The effect of perspiration on the sEMG amplitude and power spectrum.

نویسندگان

  • Mohammad Abdoli-Eramaki
  • Caroline Damecour
  • John Christenson
  • Joan Stevenson
چکیده

Sweat accumulation underneath surface EMG (sEMG) electrodes is a common problem in workplace studies which compromises electrode adherence to the skin as well as signal fidelity. In this study, the effect of sweat accumulation on signal amplitude and mean frequency (MF) was examined to determine if the sEMG signal becomes altered through the sweat layer and whether this effect can be avoided by interrupting the pool of sweat using a thin strip of medical adhesive between the electrode snaps. Nine males performed a maximum, isometric contraction of their right quadriceps as sEMG was collected. Skin conditions under the electrode were dry and wet in incremental layers of 0.02 mm of artificial sweat. The results demonstrated that sweat accumulation under sEMG electrodes dampens the amplitude of the EMG signal in a predictable way (r = .88 and .97 for double and single snap electrodes, respectively) with almost 2% and 3% deterioration for every 0.02 mm of sweat depending on the type of electrode used. The medical adhesive proved to be highly effective at preventing amplitude deterioration indicating that signal shunting can be prevented. MF was not influenced by sweat accumulation even under the extreme wet condition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contraction intensity and velocity on vastus lateralis SEMG power spectrum and amplitude.

Effect of contraction intensity [100%, 75%, 50%, and 25% maximum voluntary contraction (MVC)] and movement velocity [0 degrees (isometric)], 50 degrees, 100 degrees, 200 degrees, and 400 degrees/sec. [isovelocities]) on root mean square amplitude (SEMG-RMS) and median frequency power spectrum (SEMG-MNF) of vastus lateralis (VL) surface electromyography was investigated with ten healthy female u...

متن کامل

Effect of p-CPA Pretreatment on EEG Power Spectra in Experimental Open Brain Injury in Rats

Continuous four hours EEG (electroencephalogram) recordings and its power spectrum analysis using fast fourier transform (FFT) in urethane anesthetized male Charles Foster rats were performed in two groups: open brain injury and p-CPA (para-Chlorophenylalanine) pretreated before brain injury, respectively, and compared with the EEG power spectrum of control rats. The EEG power spectrum analysis...

متن کامل

Design of a High Range, High Efficiency Spread Spectrum Transmitter for Audio Communication Applications

This work proposes a direct sequence spread spectrum transmitter with high transmission range and efficiency for audio signals. It is shown that by choosing high process gain for spread spectrum signal the data could reach a range of 55km in the 2.4GHz ISM band. By employing a light modulation scheme, we have a relaxed SNR requirement for having a low bit error rate (BER) which translates to re...

متن کامل

Surface Electromyographic Assessment of Swallowing Function

The reliability of surface electromyographic (sEMG) variables during swallowing determines the potential usefulness of these measures in swallowing assessment and treatment. This study aimed to establish the reliability of the sEMG measures of the swallowing function of muscles during different swallowing conditions in healthy young and old volunteers. Two groups of volunteers (24 older adults,...

متن کامل

Application of statistical techniques and artificial neural network to estimate force from sEMG signals

This paper presents an application of design of experiments techniques to determine the optimized parameters of artificial neural network (ANN), which are used to estimate force from Electromyogram (sEMG) signals. The accuracy of ANN model is highly dependent on the network parameters settings. There are plenty of algorithms that are used to obtain the optimal ANN setting. However, to the best ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2012