Amplitude spectral area: predicting the success of electric shock delivered by defibrillators with different waveforms.

نویسندگان

  • Yoshihide Nakagawa
  • Yoji Sato
  • Takeshi Kojima
  • Tsutomu Wakabayashi
  • Seiji Morita
  • Mari Amino
  • Sadaki Inokuchi
چکیده

OBJECTIVES Prolonged ventricular fibrillation (VF) is associated with a low rate of return of spontaneous circulation (ROSC) following electric shock. Moreover, electric shock that does not reestablish spontaneous circulation causes myocardial dysfunction even if ROSC is subsequently achieved. Amplitude spectral area (AMSA), calculated by analysis of VF waveforms immediately before electric shock, is considered to predict the outcome of electric shock. This study aimed to evaluate the prognostic value of AMSA in relation to waveforms of defibrillators in prehospital settings. METHODS The AMSA values of 81 patients with VF confirmed by ambulance crews were compared according to the type of defibrillators with different waveforms and between those with and without ROSC. RESULTS With a biphasic defibrillator, the mean AMSA was significantly different between the 14 patients who achieved ROSC (25.3 ± 9.5 mV-Hz) and the 43 subjects who did not achieve ROSC (15.4 ± 8.1 mV-Hz; p = 0.0006). No significant difference was seen in the corresponding values when a monophasic defibrillator was used, at 19.1 ± 2.4 mV-Hz for 3 ROSC patients and 16.1 ± 7.5mV-Hz for 21 non-ROSC patients. CONCLUSION AMSA may serve as a predictive measure for ROSC following electric shock delivered by a biphasic defibrillator.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracardiac voltage gradients during transthoracic defibrillation: implications for postshock myocardial injury.

UNLABELLED In-vitro studies indicate that the electric-field intensity, or voltage gradient (VG), generated by a defibrillation shock is a determinant of defibrillation success as well as potential shock-induced cardiac injury. It is not clear how common descriptors of shock dose, e.g., joules (J), relate to VGs. OBJECTIVES To assess the relationships between shock energy descriptors and VG. ...

متن کامل

Waveform analysis of biphasic external defibrillators.

BACKGROUND AND OBJECTIVE All internal defibrillators and some external defibrillators use biphasic waveforms. The study analysed the discharged waveform pulses of two manual and two semi-automated biphasic external defibrillators. METHODS AND RESULTS The defibrillators were discharged into resistive loads of 25, 50 and 100 Omega simulating the patient's transthoracic impedance. The tested bip...

متن کامل

Scaling exponent predicts defibrillation success for out-of-hospital ventricular fibrillation cardiac arrest.

BACKGROUND -Defibrillator shocks often fail to terminate ventricular fibrillation (VF) in out-of-hospital cardiac arrest (OOHCA), and repeated failed shocks can worsen the subsequent response to therapy. Because the VF waveform changes with increasing duration of VF, it is possible that ECG analyses could estimate the preshock likelihood of defibrillation success. This study examined whether an...

متن کامل

The Role of Biphasic Shocks for Transthoracic Cardioversion of Atrial Fibrillation

The modern generation of transthoracic defibrillators now employ impedance compensated biphasic waveforms. These new devices are superior to those with monophasic waveforms and practice is currently switching to biphasic defibrillators for the treatment of both ventricular and atrial fibrillation. However, there is no universal guideline for the use of biphasic defibrillators in direct current ...

متن کامل

Electrophysiology of ventricular fibrillation and defibrillation.

The survival rate from ventricular fibrillation is very high for short-duration fibrillation (<30 secs) but decreases to approximately 3% to 30% in out-of-hospital conditions. During short-duration fibrillation, action potentials occur rapidly with no intervening period of electrical diastole; a shock defibrillates by interacting with the fibrillation action potential to produce a uniformly lon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Tokai journal of experimental and clinical medicine

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2013