Assessment of the kinematic variability among 12 motion analysis laboratories.
نویسندگان
چکیده
Variability of kinematic measurements among sites participating in a collaborative research investigation is a primary factor in determining number of subjects, level of detectable difference and statistical power of a multi-site research study. In this study, one subject was evaluated by 24 examiners at 12 motion analysis laboratories and the observed variability of nine kinematic parameters are reported. Following implementation of a standardized gait analysis protocol the same subject returned for another evaluation at each of the 12 laboratories. Additionally, system accuracy and variability of the subject within and between test days are included as factors that may affect between site variability. Marker placement among examiners is identified as the largest source of variability. A 20% decrease in variability was noted following implementation of the standardized protocol.
منابع مشابه
Assessment of the Kinematic Variability between Twelve Shriners Motion Analysis Laboratories
Introduction The field of motion analysis does not currently have any formal standards for data collection, communication of information, or quality assurance across multiple laboratories. Historically, laboratories have developed with little or no direct collaboration with other facilities. Efforts at multicenter research have been limited for many reasons, including inconsistent evaluation pr...
متن کاملEvaluation of Gait Variability in Deafness and Comparing it with Normal-hearing Listeners After a Course of Interventional Proprioceptive Training
Objective: Gait variability index is an important index in the clinical treatment of people with walking problems. Since the variability of gait behavior in deaf people has not been evaluated so far, the purpose of this study was to evaluate the walking variability of deaf people and compare it with normal-hearing listeners. Methods: The statistical population of this study was deaf and hearin...
متن کاملI-4: External Quality Assessment - A Necessity in The Andrology Laboratory
Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...
متن کاملDesigning, validation, and reliability assessment of software to acquire kinematics parameters of motion by image processing
Motion analysis systems are useful and effective equipment in biomechanics research. Unfortunately these systems are available for few researchers because these are expensive equipment. The aim of this study was to design and validation of a practical and inexpensive software, to determine the exact markers position in space and compute the kinematic of movement. In designing the software, the ...
متن کاملThe in vitro effects of nanosilver colloid on kinematic parameters of ram spermatozoa
This study investigated the concentration/time dependent effects of nanosilver colloid on the motionparameters of the ejaculated ram spermatozoa in vitro. After incubation of sperm samples for 30, 60, 120 and 180 min in the presence of nanosilver colloid (0, 0.001, 0.01, 0.1, 1 and 10 ppm), the motion parameters were evaluated by computer assisted sperm analysis. There was a significant (P