Predictive value of robotic-assisted total hip arthroplasty.

نویسندگان

  • Youssef F El Bitar
  • Timothy J Jackson
  • Dror Lindner
  • Itamar B Botser
  • Christine E Stake
  • Benjamin G Domb
چکیده

Acetabular cup positioning, leg-length discrepancy, and global offset are important parameters associated with outcomes following total hip arthroplasty (THA). Deviation from an accepted range of values can lead to significant complications, including dislocation, leg-length discrepancy, impingement, accelerated bearing surface wear, and revisions. The purpose of this study was to assess whether robotic-assisted THA was reliable in predicting radiographic measurements of cup inclination and anteversion, leg-length change, and global offset change. All 61 robotic-assisted THAs that met the inclusion and exclusion criteria were performed by a single surgeon through a mini-posterior approach. Data provided by the robot were collected prospectively, and radiographic data were collected retrospectively by 2 blinded independent reviewers. The cohort in this study consisted of 27 male and 34 female patients, with an average age of 60.5 years. A strong inter- and intraobserver correlation was found for the radiographic measurements of cup inclination, cup anteversion, leg-length discrepancy, and global offset (r>0.8 with P<.001 for all). Ninety-six point seven percent of robotic-measured inclination angles and 98.4% of robotic-measured anteversion angles were within 10° of radiographic measurements. One hundred percent of robotic-measured leg-length change and 91.8% of robotic-measured global offset change were within 10 mm of radiographic measurements. Robotic-assisted THA showed good predictive value for cup inclination and anteversion angles and measurements of leg-length change and global offset change done postoperatively on plain radiographs. Further refinement of the robotic system would make it more accurate in predicting the postoperative parameters mentioned.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer-assisted hip and knee arthroplasty. Navigation and active robotic systems: an evidence-based analysis.

OBJECTIVE The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. THE TECHNOLOGY Computer-assisted arthroplasty consists of navigation and...

متن کامل

Robotic systems in total hip arthroplasty--is the time ripe for a new approach?

The technical aspects of manual total hip arthroplasty are briefly described. The development, technique and technical problems of previous robotic systems in total hip arthroplasty are described with special details of the Robodoc--System. Recent advances regarding the minimally invasive technique of total-hip implantation and navigation are described. The current development of a robotic assi...

متن کامل

Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study.

Obese populations present challenges for acetabular cup placement during total hip arthroplasty (THA). This study examines the accuracy of acetabular cup inclination and version in the obese patient with robotic-assisted computer navigation. A total of 105 patients underwent robotic-assisted computer navigation THA with a posterior approach. Groups were divided on body mass index (BMI, kg/m(2))...

متن کامل

Accuracy of Component Placement in Robotic-Assisted Total Hip Arthroplasty.

Robotic-assisted total hip arthroplasty (THA) is a recent platform introduced to decrease the risk of malpositioned components. The goals of this study were to determine whether intraoperative data on robotic-assisted THA acetabular component position accurately predict postoperative radiographic acetabular component position and to determine whether intraoperative data on robotic-assisted THA ...

متن کامل

Robotic Total Knee Arthroplasty: Surgical Assistant for a Customized Normal Kinematic Knee.

Although current total knee arthroplasty (TKA) is considered a highly successful surgical procedure, patients undergoing TKA can still experience substantial functional impairment and increased revision rates as compared with those undergoing total hip arthroplasty. Robotic-assisted surgery has been available clinically for almost 15 years and was developed, in part, to address these concerns. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2015