Hybrid TEM/Loop Coil Array for Parallel High Field MRI
نویسندگان
چکیده
Introduction As B0 field strengths increase, there is an almost linear increase in SNR. However, new problems arise at higher field strengths, such as a higher SAR and B1-field inhomogeneity. To counteract these problems, multiple transmit channels are necessary to improve the image homogeneity, this can be achieved with static RF-shimming [1]. In this work, a new transceive surface coil array is investigated made up of hybrid coil elements [2]. The single hybrid coil element consists of a TEM and a loop coil, which are geometrically decoupled, and locally produce a circularly polarized field. Because each hybrid coil element has its own shield, the hybrid coil array is configurable and acts as a building block for coil arrays to image different parts of the body. Experiments & Methods A 4-element hybrid coil array was designed and constructed for the imaging of the head at 3T. Because the TEM and loop coil on this hybrid coil element are geometrically decoupled, additional decoupling circuitry is not necessary. The TEM coil has a lower sensitivity and is placed above the loop coil. To reduce coupling between neighboring hybrid coils, additional copper side shields were added to the RF-shield. Each hybrid coil element has its own RF-shield to reduce radiation loss. The unloaded Q-factor, measured with a network analyzer, was 360 for the TEM coil and 400 for the loop coil. 50Ω-matching was performed by inductive coupling to reduce cable currents. Remaining cable currents at the Larmor frequency were successfully reduced using cable traps. The sideshields were optimized to reduce the maximal coupling to −12 dB (occurring between neighboring TEM coils). The hybrid coil array was matched to a spherical phantom and successfully tested on a Philips 3T Achieva scanner with eight independent transmit channels developed at the Philips Research Laboratories in Hamburg [3]. The spherical phantom had a radius of 10 cm, εr=50, and σ=0.5S/m. The complex transmit sensitivities in the transversal plane were computed from the experimental data. The measured complex transmit sensitivities were consistent with the simulated results using a MoM solver. Therefore, we can use the simulations to further investigate the coil array. The excitation voltages for the homogeneous drive (minimizing the normalized standard deviation sn of the B1 -field, with input power of unity) were computed with an optimization program in MATLAB based on optimizations described in [4], and compared to the homogeneous drives of a 4-TEM and 4-loop array with the same dimensions (Fig. 3). Fig. 3a shows the simulated homogenized transmit fields of the 4-element head coil array prototype using hybrid coil elements (1 row), TEM elements (2 row), and loop coil elements (3 row). The use of a 6-element body coil array for body imaging (elliptically cylindrical phantom, short axis 23 cm, long axis 50 cm, length 1m) was investigated in the same way, see Fig. 3b. Here the coil elements were placed 7 cm away from the phantom for a more homogeneous transmit field. Additionally, the hybrid coil array for head imaging was optimized in the simulation by varying the height of the TEM and the loop coil above the RF-shield. Shown in Fig. 4 are the normalized standard deviation sn, the input power needed to achieve a 90 degree flip angle in the center, the minimum intrinsic transceive SNR, and the maximum and average noise amplification factors for SENSE imaging with reduction factor of R=3 as a function of distance coil to the RF-shield hTEM and hloop. The intrinsic transceive SNR is computed as:
منابع مشابه
Improved B1+ field using a 16-channel Transmit Head Array and an 8-channel pTx System at 7T
INTRODUCTION At 7T, transmit coil arrays using parallel transmit (pTx) [1] systems enable techniques to substantially improve B1 transmit fields. Receive coil arrays offer enhanced sensitivity and parallel imaging performance. However, significant challenges in ultra high field systems are still remaining for the design and implementation of RFcoils for dedicated transmit channels and their int...
متن کاملA modelling study of a Hybrid Loop-Strip coil structure for multichannel Transceive Breast Array Coil
Introduction Magnetic Resonance Imaging (MRI) has become a very important technique for the diagnosis of breast diseases. A dedicated radio frequency (RF) coil, capable of inducing a homogeneous magnetic field within a defined region of interest as well as receiving MRI signals with a high signal to noise ratio (SNR), is essential for high spatial resolution breast imaging. Close-fitting phased...
متن کاملDesign and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.
PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...
متن کاملNumerical Evaluation of an 8-element Phased Array Torso Coil for Magnetic Resonance Imaging
Recently, parallel imaging using multiple RF coils has excited great interest in magnetic resonance imaging (MRI). To help the design of some novel flexible array coils for the human torso, we theoretically investigate the RF field of an 8-element array coil loaded with an anatomically accurate model of the human torso. The RF behaviour is predicted based on a hybrid FDTD/MoM approach. The prim...
متن کاملA Novel 8-Channel Transceive Volume-Array for a 9.4T Animal Scanner
Introduction This work focuses on the design of a novel 8-element TX/RX volume-array for high field animal MRI. The magnetic field strength of current small animal MRI systems is increasing in search of higher SNR and spectral resolution [1]. Along with the move to higher field strengths, RF coil design for small-animal MRI is advancing concurrently [2]. At ultra high field strengths, however, ...