Design and Validation of a Cyclic Strain Bioreactor to Condition Spatially-Selective Scaffolds in Dual Strain Regimes

نویسندگان

  • J. Matthew Goodhart
  • Jared O. Cooper
  • Richard A. Smith
  • John L. Williams
  • Warren O. Haggard
  • Joel D. Bumgardner
چکیده

The objective of this study was to design and validate a unique bioreactor design for applying spatially selective, linear, cyclic strain to degradable and non-degradable polymeric fabric scaffolds. This system uses a novel three-clamp design to apply cyclic strain via a computer controlled linear actuator to a specified zone of a scaffold while isolating the remainder of the scaffold from strain. Image analysis of polyethylene terephthalate (PET) woven scaffolds subjected to a 3% mechanical stretch demonstrated that the stretched portion of the scaffold experienced 2.97% ± 0.13% strain (mean ± standard deviation) while the unstretched portion experienced 0.02% ± 0.18% strain. NIH-3T3 fibroblast cells were cultured on the PET scaffolds and half of each scaffold was stretched 5% at 0.5 Hz for one hour per day for 14 days in the bioreactor. Cells were checked for viability and proliferation at the end of the 14 day period and levels of glycosaminoglycan (GAG) and collagen (hydroxyproline) were measured as indicators of extracellular matrix production. Scaffolds in the bioreactor showed a seven-fold increase in cell number over scaffolds cultured statically in tissue culture plastic petri dishes (control). Bioreactor scaffolds showed a lower concentration of GAG deposition per cell as compared to the control scaffolds largely due to the great increase in cell number. A 75% increase in hydroxyproline concentration per cell was seen in the bioreactor stretched scaffolds as compared to the control scaffolds. Surprisingly, little differences were experienced between the stretched and unstretched portions of the scaffolds for this study. OPEN ACCESS Processes 2014, 2 346 This was largely attributed to the conditioned and shared media effect. Results indicate that the bioreactor system is capable of applying spatially-selective, linear, cyclic strain to cells growing on polymeric fabric scaffolds and evaluating the cellular and matrix responses to the applied strains.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Using a Multi-Strain Probiotic on Performance, Immune Responses and Cecal Microflora Composition in Broiler Chickens Reared Under Cyclic Heat Stress Condition

This experiment was conducted to examine the effect of multi-strain probiotic (Primalac) on performance, immune responses and cecal microflora in broiler chickens under cyclic heat stress condition. A total of 96 one-d-old mixed sex broiler chicks (Ross 308) were weighed and randomly allocated to two treatment groups, each with 4 replicate pens of 12 chicks. The dietary treatments were basal di...

متن کامل

Effect of Uniaxial Tensile Cyclic Loading Regimes on Matrix Organization and Tenogenic Differentiation of Adipose-Derived Stem Cells Encapsulated within 3D Collagen Scaffolds

Adipose-derived mesenchymal stem cells have become a popular cell choice for tendon repair strategies due to their relative abundance, ease of isolation, and ability to differentiate into tenocytes. In this study, we investigated the solo effect of different uniaxial tensile strains and loading frequencies on the matrix directionality and tenogenic differentiation of adipose-derived stem cells ...

متن کامل

Optimization of Bioreactor Cultivation Parameters by Taguchi Orthogonal Array Design for Enhanced Prodigiosin Production

One of the major steps toward the industrialization of the microbial product(s) is to optimize the cultivation conditions at the large-scale bioreactor and successfully control the microbial behavior within a large scale production environment. Statistical Design of Experiment was proven to optimize a vast number of microbial processes to achieve robustness and explore possible interactions...

متن کامل

Numerical investigation of strain distribution during cyclic expansion extrusion (CEE)

Strain distribution of Al 1100 was numerically investigated during cyclic expansion extrusion (CEE) process using finite element method (FEM). Die angle, corner fillet radius and die chamber diameter were considered as die parameters and friction factor and number of passes as process parameters. The effects of these parameters were investigated on the effective strain and strain homogeneity in...

متن کامل

A Strain Range Dependent Cyclic Plasticity Model

Hysteresis loop curves are highly important for numerical simulations of materials deformation under cyclic loadings. The models mainly take account of only the tensile half of the stabilized cycle in hysteresis loop for identification of the constants which don’t vary with accumulation of plastic strain and strain range of the hysteresis loop. This approach may be quite erroneous particularly ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014