THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation

نویسندگان

  • L. Arazi
  • Natal da Luz
  • J. M. F. dos Santos
  • C. D. R. Azevedo
  • D. S. Covita
  • C. A. B. Oliveira
  • J. F. C. A. Veloso
  • M. Breidenbach
  • D. Freytag
  • G. Haller
  • R. Herbst
  • S. Park
  • A. White
  • J. Yu
  • E. Oliveri
چکیده

We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm 2 prototype detector with 1 cm 2 readout pads. The detector is comprised of singleor double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 10 -6 -10 -5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2x10 -6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

آشکارسازی پرتوهای آلفا با استفاده از کارکرد آشکارسازهای گازی مقیاس ریز در مد SQS

In gas detectors with UV absorbing gas mixture, the Self-Quenched Streamer (SQS) mode can be achieved following the proportional mode, which leads to appear the light column. In this study, the design, simulation and construction of three micro pattern gas-detector, THGEM, with different geometric dimensions are presented. Moreover, the ability of operation in SQS mode to determine incident ray...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Development of THGEM-based photon detectors for Cherenkov Imaging Counters

The development of a large size gaseous detector of single photons, able to stably operate at high gain and high rate, and to provide good time resolution and insensitivity to magnetic field would be beneficial to future Cherenkov Imaging Counters. The detector could be based on the use of a multilayer architecture of THGEM electron multipliers coupled to a solid state CsI photocathode. A syste...

متن کامل

Thick GEM versus thin GEM in two-phase argon avalanche detectors

The performance of thick GEMs (THGEMs) was compared to that of thin GEMs in two-phase Ar avalanche detectors, in view of their potential application in coherent neutrino-nucleus scattering, dark-matter search and in other rare-event experiments. The detectors comprised a 1 cm thick liquid-Ar layer followed by either a double-THGEM or a triple-GEM multiplier, operated in the saturated vapor abov...

متن کامل

طراحی و ساخت آشکارسازRETGEM سه گانه

The aim of this paper is to design, manufacture and test the first triple RETGEM detector. Using resistive electrode in RETGEM detectors made them more robust against the electrical discharge with respect to THGEM detectors. However, even these robust detectors are not protected against electrical discharge at gains higher than 105. Studying the role of dimensions of the triple RETGEMS detector...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011