In this work, a fast, simple and economic method is proposed for the determination of imazalil in water samples by flow injection photoinduced chemiluminescence. In this method, imazalil degrades in basic media through the use of a photoreactor, and the resulting photofragments react with ferricyanide and generate the direct chemiluminescence signal. To the authors' knowledge, this is the first time that a chemiluminescence method has been proposed for the determination of this fungicide. All physical and chemical parameters in the flow injection chemiluminescence system were optimized in the experimental setting. In the absence of preconcentration, the linear dynamic range for imazalil was 0.75-5 mg L(-1) and the detection limit was 0.171 mg L(-1). The application of solid-phase extraction with C18 cartridges allowed the elimination of interference ions, the reduction of the linear dynamic range to 15-100 μg L(-1), and a detection limit of 3.4 μg L(-1). This detection limit is below the maximum concentration level established by the Regulations of the Hydraulic Public Domain for pesticide dumping. The sample throughput after solid-phase extraction of the analyte was 12 samples h(-1). The intraday and interday coefficients of variation were below 9.9% in all cases. This method was applied to the analysis of environmental water samples, and recoveries of between 95.7 and 110% were obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FI-photoinduced chemiluminescence method for diuron determination in water samples.

A new method for the determination of the herbicide diuron, using a flow injection manifold and photoinduced chemiluminescence detection, is presented. The pesticide, in basic medium, was irradiated on-line with UV light (254 nm) for 53 s. A short discussion about the possible irradiation products is included. The chemiluminescent response of the photoproducts was induced by oxidation with pota...

متن کامل

Fast determination of thiacloprid by photoinduced chemiluminescence.

A new and sensitive application of chemiluminescence detection has been developed for the determination of the pesticide thiacloprid in water. It was based on the on-line photoreaction of thiacloprid in a basic medium, with quinine acting as the sensitizer of the chemiluminescent response; cerium (IV) in sulfuric acid medium was used as the oxidant. High degrees of automation and reproducibilit...

متن کامل

Native vs photoinduced chemiluminescence in dimethoate determination.

The determination of dimethoate using either its native chemiluminescent (CL) properties or its photoinduced chemiluminescence obtained by irradiation with a 15 W low-pressure mercury lamp was studied. Thereby, two flow injection systems (FIA) with and without irradiation were exhaustively optimized and their analytical characteristics studied. Better sensitivity and selectivity was found in ab...

متن کامل

Selective and Sensitive Chemiluminescence Determination of Mcpb: Flow Injectin and Liquid

Two new chemiluminescence methods are described for the determination of herbicide MCPB. Firstly, a flow injection chemiluminescence (FI-CL) method is proposed. In this method, MCPB is photodegraded with a UV lamp and the photoproducts formed provide a great chemiluminescence signal when they react with ferricyanide in basic medium. Secondly, an HPLC chemiluminescence (HPLC-CL) method is propos...

متن کامل

Development of a Photoinduced Chemiluminescent Method for the Determination of the Herbicide Quinmerac in Water.

A new, simple, and sensitive method, based on photoinduced chemiluminescence, was developed for the determination of quinmerac. The photoproduct, obtained after ultraviolet irradiation in basic medium, was mixed with sodium sulfite (sensitizer), and Ce(IV) (oxidant) in acid medium. A wide linear dynamic range (2-600 ng mL(-1)) and a limit of detection of 0.6 ng mL(-1) were obtained without any ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 398 7-8  شماره 

صفحات  -

تاریخ انتشار 2010