Hemodynamic evaluation of heart valve prostheses paradigm shift for transcatheter valves?
نویسندگان
چکیده
l p he treatment of aortic valve disease is undergoing rapid hanges. In addition to conventional valve replacement that as evolved as the gold standard over several decades, ranscatheter techniques have been introduced into clinical ractice. Whereas the conventional approach offers very recise and safe suturing of standard valves with low failure ates and excellent proven long-term outcomes, transcathter techniques allow for off-pump beating-heart valve mplantations that can even be performed without general nesthesia in some patients. To determine the clinical benefits f transcatheter valve implantation in comparison with conentional aortic valve surgery, randomized trials are required.
منابع مشابه
Transcatheter Aortic Valve Implantation
During the past decades, the only effective treatment option for severe, symptomatic, aortic valve stenosis was surgical aortic valve replacement. More than 10 years ago, Alain Cribier performed the first transcatheter aortic valve implantation (TAVI). Since 2007, CE-mark certified aortic valves are available for TAVI. This new technology rapidly achieved a very high clinical acceptance as a tr...
متن کامل1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves: Results From the CHOICE Randomized Clinical Trial.
BACKGROUND The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. OBJECTIVES The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. METHODS The investigator-initiated trial randomized 241 high-risk patients with symptomati...
متن کاملInjectable Tissue-Engineered Pulmonary Heart Valve Implantation Into the Pig Model: A Feasibility Study
BACKROUND Transcatheter pulmonary valve replacement is currently performed in clinical trials, however limited by the use of glutaraldehyde treated bioprostheses. This feasibility study was performed to evaluate delivery-related tissue distortion during implantation of a tissue engineered (TE) heart valves. MATERIAL AND METHOD The injectable TE heart valve was mounted on a self-expanding niti...
متن کاملPercutaneous mitral valve replacement using a transvenous, transseptal approach: transvenous mitral valve replacement.
OBJECTIVES The aim of this paper is to describe the feasibility of a novel transcatheter approach for mitral valve replacement using only venous access. BACKGROUND Failure of mitral valve prostheses necessitating reoperation can represent a high-risk clinical scenario. Although repeat cardiac surgery remains the standard of care for most failed mitral valve operations, nascent transcatheter o...
متن کاملAortic regurgitation after transcatheter aortic valve replacement.
Paravalvular aortic regurgitation (AR) negatively affects prognosis following transcatheter aortic valve replacement (TAVR). As transcatheter heart valves (THV) are anchored using a certain degree of oversizing at the level of the aortic annulus, incomplete stent frame expansion because of heavily annular calcifications, suboptimal placement of the prosthesis, and/or annulus-prosthesis size-mis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 53 20 شماره
صفحات -
تاریخ انتشار 2009