A novel radiographic targeting guide for percutaneous placement of transfacet screws in the cervical spine with limited fluoroscopy: A cadaveric feasibility study

نویسندگان

  • David M. Jackson
  • Jacqueline E. Karp
  • Joseph R. O'Brien
  • D. Greg Anderson
  • Daniel E. Gelb
  • Steven C. Ludwig
چکیده

BACKGROUND We describe a technique for percutaneous transfacet screw placement in the cervical spine without the need for lateral-view fluoroscopy. METHODS Previously established articular pillar morphometry was used to define the ideal trajectory for transfacet screw placement in the subaxial cervical spine. A unique targeting guide was developed to allow placement of Kirschner wires across the facet joint at 90° without the guidance of lateral-view fluoroscopy. Kirschner wires and cannulated screws were placed percutaneously in 7 cadaveric specimens. Placement of instrumentation was performed entirely under modified anteroposterior-view fluoroscopy. All specimens were assessed for acceptable screw placement by 2 fellowship-trained orthopaedic spine surgeons using computed tomography. Open dissection was used to confirm radiographic interpretation. Acceptable placement was defined as a screw crossing the facet joint, achieving purchase in the inferior and superior articular processes, and not violating critical structures. Malposition was defined as a violation of the transverse foramen, spinal canal, or nerve root or inadequate fixation. RESULTS A total of 48 screws were placed. Placement of 45 screws was acceptable. The 3 instances of screw malposition included a facet fracture, a facet distraction, and a C6-7 screw contacting the C7 nerve root in a specimen with a small C7 superior articular process. CONCLUSIONS Our data show that with the appropriate radiographic technique and a targeting guide, percutaneous transfacet screws can be safely placed at C3-7 without the need for lateral-view fluoroscopy during the targeting phase. Because of the variable morphometry of the C7 lateral mass, however, care must be taken when placing a transfacet screw at C6-7. CLINICAL RELEVANCE This study describes a technique that has the potential to provide a less invasive strategy for posterior instrumentation of the cervical spine. Further investigation is needed before this technique can be applied clinically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mini-open or percutaneous bilateral lumbar transfacet pedicle screw fixation: a technical note.

STUDY DESIGN Case report. OBJECTIVE To describe the technique used to place bilateral lumbar transfacet pedicle screws. SUMMARY OF BACKGROUND DATA Transfacet pedicle screw fixation is a growing alternative and biomechanically comparable with traditional pedicle screw fixation. There is no clear description of technique steps for placing transfacet pedicle screws available in the literature,...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

A Novel Patient-Specific Drill Guide Template for Pedicle Screw Insertion into the Subaxial Cervical Spine Utilizing Stereolithographic Modelling: An In Vitro Study

STUDY DESIGN Cadaveric study. PURPOSE The purpose of this study was to assess the accuracy and feasibility of cervical pedicle screw (CPS) insertion into the subaxial cervical spine placed using a patient-specific drill guide template constructed from a stereolithographic model. OVERVIEW OF LITERATURE CPS fixation is an invaluable tool for posterior cervical fixation because of its biomecha...

متن کامل

Biomechanics of posterior instrumentation in L1-L3 lateral interbody fusion: Pedicle screw rod construct vs. transfacet pedicle screws.

BACKGROUND The use of pedicle screws is the gold standard for supplemental posterior fixation in lateral interbody fusion. Information about the performance of transfacet pedicle screws compared to standard pedicle screws and rods in the upper lumbar spine with or without a lateral interbody fusion device in place is limited. METHODS Fifteen fresh frozen human cadaveric lumbar spine segments ...

متن کامل

Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws.

STUDY DESIGN Randomized laboratory cadaver study. OBJECTIVE The objective of this study was to determine the accuracy of anterior transpedicular screw placement in the cervical spine using conventional fluoroscopy versus computer-assisted navigation. SUMMARY OF BACKGROUND DATA Traditionally, global cervical instability has required anterior and posterior fixation due to the superior biomech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012