Functional assessment of high-grade ICA stenosis with duplex ultrasound and transcranial Doppler

نویسندگان

  • Helene Zachrisson
  • Marita Fouladiun
  • Christian Blomstrand
  • Jan Holm
  • Reinhard Volkmann
چکیده

BACKGROUND Duplex ultrasound (DUS) has shown a >90% accuracy compared to angiography, concerning the degree of internal carotid artery (ICA) stenosis. However, uncertainty may occur in a severe stenosis, in which peak systolic velocity (PSV) may decrease owing to high flow resistance or high backward pressure. We investigated intracranial collateral flows using transcranial Doppler (TCD) to further evaluate the hemodynamic significance of high-grade ICA stenosis. METHODS In this retrospective study, 320 consecutive symptomatic patients were examined. The degree of ICA stenosis and collateral capacity in the circle of Willis was investigated by DUS and TCD. In addition, magnetic resonance angiography (MRA) was added in a subgroup of 204 patients. The criterion for hemodynamic significant ICA stenosis was established collateral flow. RESULTS In 91% of all symptomatic vessels (291 vessels), an ICA stenosis of ≥70% was found. Established collateral flow always indicated precerebral carotid artery disease of ≥70%. Furthermore, in 11% of the whole study material, collateral reserve capacity was found despite high-grade (≥70%) ICA stenosis. PSV in ICA <2·5 m s(-1) was combined with established collateral flow and MRA stenosis of ≥70% in 9% (19 arterial systems). In 4%, doubt existed concerning the degree of stenosis after DUS. CONCLUSION Transcranial Doppler helps to determine whether an ICA stenosis is of hemodynamic significance and to assess collateral patterns. Established collateral blood flow will help to identify patients with ≥70% (ECST) carotid artery disease. TCD might be of value when flow velocity criteria combined with plaque assessment by DUS are inclusive. Other diagnostic methods may also be considered.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benefit of echocontrast-enhanced transcranial color-coded duplex ultrasound in the assessment of intracranial collateral pathways.

BACKGROUND AND PURPOSE Although clinically important, proper assessment of intracranial arterial collateral pathways by transcranial color-coded duplex sonography (TCCD) in patients with internal carotid artery (ICA) high-grade stenosis or occlusion is occasionally made difficult by an insufficient temporal bone window, an unfavorable insonation angle, or low flow velocity or volume. In these c...

متن کامل

Power M-Mode Doppler and single-gate spectral analysis using a 2-MHz pulsed-wave Doppler transducer to directly detect cervical internal carotid artery stenosis: use of the continuity principle: report of a novel technique.

BACKGROUND AND PURPOSE We hypothesized that direct cervical investigation with Power M-Mode Doppler (PMD) combined with single-gate Doppler spectral analysis (SGDSA) using a 2-MHz pulsed-wave Doppler transducer would show reasonable accuracy parameters when compared with standard color-coded carotid duplex ultrasound (CDU). METHODS We prospectively screened for cervical internal carotid arter...

متن کامل

Inflammation in high-grade carotid stenosis: a possible role for macrophages and T cells in plaque destabilization.

BACKGROUND AND PURPOSE Inflammatory mechanisms have been implicated in the pathogenesis of atherosclerosis. In this study, we investigated whether the extent of inflammatory infiltration in high-grade stenoses of the internal carotid artery (ICA) correlates to clinical features of plaque destabilization. METHODS Endarterectomy specimens from 37 consecutive patients undergoing surgery for high...

متن کامل

Transcranial color-coded duplex sonography for detection of distal internal carotid artery stenosis.

BACKGROUND AND PURPOSE Gradation of high-grade intracranial internal carotid artery (ICA) stenosis poses a challenge to noninvasive neurovascular imaging, which seems critical for angioplasty in the ICA segments C1 and C5. We investigated cutoff values of intracranial ICA stenosis for transcranial color-coded sonography (TCCS) and compared this method with the "gold standard," digital subtracti...

متن کامل

Diagnostic performance of duplex ultrasonography in the detection of high grade internal carotid artery stenosis.

OBJECTIVES to establish on a national basis whether the diagnostic accuracy of carotid duplex justifies carotid surgery without preoperative angiography. DESIGN prospective national multicentre study with 10 participating university and county hospitals. MATERIAL AND METHODS one hundred and thirty-four patients, aged 69+/-9 years, were subjected to routine carotid duplex ultrasonography and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2012