Linear Regression Analysis of 2 D Projection Image Data of 6 Degrees - of - Freedom ArcHNES Transformed 3 D Image Sets for Stereotactic Radiation Therapy

نویسنده

  • Richard C. Lanza
چکیده

Patient positioning is crucial to accurate dose delivery during radiation therapy to ensure the proper localization of dose to the target tumor volume. In patient positioning for stereotactic radiation therapy treatment, classical image registration methods are computationally costly and imprecise. We developed an automatic, fast, and robust 2D-3D registration method to improve accuracy and speed of identifying 6 degrees-of-freedom (DoF) transformations during patient positioning for stereotactic radiotherapy by creating a model of characteristic shape distributions to determine the linear relationship between two real-time orthogonal 2D projection images and the 3D volume image. We defined a preprocessed sparse base set of shape distributions that characterize 2D digitally reconstructed radiograph (DRR) images from a range of independent transformations of the volume. The algorithm calculates the 6-DoF transformation of the patient based upon two orthogonal real-time 2D images by correlating the images against the base set The algorithm has positioning accuracy to at least 1 pixel, equivalent to 0.5098 mm accuracy given this image resolution. The shape distribution of each 2D image is created in MATLAB in an average of 0.017 s. The online algorithm allows for rapid and accurate position matching of the images, providing the transformation needed to align the patient on average in 0.5276 s. The shape distribution algorithm affords speed, robustness, and accuracy of patient positioning during stereotactic radiotherapy treatment for small-order 6-DoF transformations as compared with existing techniques for the quantification of patient setup where both linear and rotational deviations occur. This algorithm also indicates the potential for rapid, high precision patient positioning from the interpolation and extrapolation of the linear relationships based upon shape distributions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Morphological Characteristics of Raw Cane Sugar Crystals Using Digital Image Analysis

Raw cane sugar is one of the most important product in the sugar industry and is the main raw material for the white sugar production. Morphological and physical properties of this product might influence the final white sugar. For instance, the behavior during centrifugation, transport and storage is related to the characteristics of these crystals. The object of this study was to determine th...

متن کامل

ایجاد تصویر سه بعدی با استفاده از سیستم های فراصوت دو بعدی معمولی

Ultrasound imaging is one of the common methods in medical diagnostic    systems. There are many artifacts in a two dimentional image. Three dimentional    imaging can be used for better interpretation and perception of an image. Since    1969 many attemps have been made in this regards, and research continues all    over the world. The main goal in...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

Stress Field Analysis of V-Notches with Tip Cracks in a Polymer Material Using Digital Image Correlation

In this study, displacement field around v-notches of a poly methyl metha crylate (PMMA) specimen with tip cracks will be analyzed using digital image correlation technique. First intensity factor in combination with in-plane rigid body translations and rotation components will be determined by linear least squares fitting of the displacement field data to the corresponding relations among stre...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012