Pannus formation on St. Jude Medical prosthetic aortic valve 23 years after initial operation.
نویسندگان
چکیده
Fig. 1. Removed SJM valve; circumferential pannus extended into both on inflow (a) and outflow (b) side of the valve over the pivot guard. * Corresponding author. Address: Department of Cardiovascular Surgery, Seirei Hamamatsu General Hospital, 2-12-12, Sumiyoshi, Naka-ku, Hamamatsu-shi, Shizuoka 430-8558, Japan. Tel.: +81 53 474 2222; fax: +81 53 471 6050. E-mail address: [email protected] (T. Sugiura).
منابع مشابه
Valve dysfunction of the cloth-covered Starr-Edwards ball valve.
BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...
متن کاملLong-term outcomes after St. Jude Medical mechanical valve implantation.
patient-year), major bleeding events (1.0%/patient-year), and aortic valve reoperation (0.26%/patient-year). They also reported that valve-related death was the most common cause of death (26.8%) and that the rates of freedom from valve-related death were 96.2%, 92.7%, 88.8%, and 86.6% at 5, 10, 15, and 20 years, respectively. These results compare favorably with the findings of previous report...
متن کاملProsthetic valve obstruction at Tygerberg Hospital between January 1991 and February 2001.
BACKGROUND Prosthetic valve obstruction is a relatively rare, but potentially fatal complication in patients with prosthetic heart valves. The diagnosis and appropriate management of these patients present a challenge to both the cardiologist and the cardiac surgeon. Despite efforts over the last 30 years to prevent this complication, it remains a lifelong risk. Obstruction is caused by pannus ...
متن کاملParoxysmal mechanical aortic valve prosthesis dysfunction: capturing the right moment
A 62-year-old female presented to the emergency room under suspicion of acute myocardial infarction. While shopping she suddenly experienced severe chest pain and nearly collapsed. Her medical history revealed aortic valve replacement (Medtronic Hall 22 mm) 8 years before and since 5 years repeated presentations to the emergency room because of intermittent chest pain. An initial electrocardiog...
متن کاملObstruction of mechanical heart valve prostheses: clinical aspects and surgical management.
One hundred patients (32 male) aged 5 months to 82 years (median 32 years) underwent 106 surgical procedures for 112 mechanical prosthetic valves obstructed by a thrombus (n = 61) or pannus (n = 7), or both (n = 44), between January 1, 1980 and December 31, 1989. The position of the obstructed prosthesis was aortic in 51 patients (48%), mitral in 49 (46%) and both aortic and mitral in 6 (6%). T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 33 5 شماره
صفحات -