Gaseous microemboli in cardiac surgery with cardiopulmonary bypass: the use of veno-arterial shunt as a preventive method.
نویسندگان
چکیده
Neurological complications are an important cause of morbidity in the postoperative period of cardiac surgery and its incidence reaches up to 75% of patients. An important cause of these events is the formation of microbubbles in the bloodstream during cardiopulmonary bypass. Integrative review was carried out on gaseous microemboli in cardiopulmonary bypass. This study analyzed studies with different methodological approaches, but that address the issue. The result suggests the denitrogenation of blood by hyperoxia dissolved microbubbles in the blood and venoarterial shunt can balance the respiratory parameters changed with hyperoxia.
منابع مشابه
Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation.
The detection and prevention of gaseous microemboli (GMEs) during cardiopulmonary bypass has generated considerable interest within the cardiac surgical community. There have been several landmark papers that have used transcranial Doppler devices during cardiopulmonary bypass to detect gaseous microemboli activity in the patients' middle cerebral artery during perfusionist interventions. To de...
متن کاملVacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.
When conventional gravity siphon venous drainage cannot achieve satisfactory venous drainage during minimally invasive cardiac and neonatal surgeries, assisted venous drainage techniques are needed to ensure adequate flow. One assisted venous drainage technique, vacuum-assisted venous drainage (VAVD), the aid of a vacuum in the venous reservoir, is now widely used to augment venous drainage dur...
متن کاملArterial Limb Microemboli during Cardiopulmonary Bypass: Observations from a Congenital Cardiac Surgery Practice.
Gaseous microemboli (GME) are known to be delivered to the arterial circulation of patients during cardiopulmonary bypass (CPB). An increased number of GME delivered during adult CPB has been associated with brain injury and postoperative cognitive dysfunction. The GME load in children exposed to CPB and its consequences are not well characterized. We sought to establish a baseline of arterial ...
متن کاملGaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.
Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller v...
متن کاملComparison of gaseous microemboli counts in arterial, simultaneous and venous heat exchange with a hollow fiber membrane oxygenator.
Potential sources of gaseous microemboli during cardiopulmonary bypass are varied. However, it is known that membrane oxygenators generate fewer gaseous microemboli than bubble oxygenators and that bubblers cannot utilize arterial heat exchange without generating significant gaseous microemboli during rewarming. A membrane oxygenator utilizing simultaneous gas and heat exchange raises the con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2012