Fractional modeling of viscoelasticity in 3D cerebral arteries and aneurysms

نویسندگان

  • Yue Yu
  • Paris Perdikaris
  • George E. Karniadakis
چکیده

We develop efficient numerical methods for fractional order PDEs, and employ them to investigate viscoelastic constitutive laws for arterial wall mechanics. Recent simulations using one-dimensional models [1] have indicated that fractional order models may offer a more powerful alternative for modeling the arterial wall response, exhibiting reduced sensitivity to parametric uncertainties compared with the integer-calculus-based models. Here, we study three-dimensional (3D) fractional PDEs that naturally model the continuous relaxation properties of soft tissue, and for the first time employ them to simulate flow structure interactions for patient-specific brain aneurysms. To deal with the high memory requirements and in order to accelerate the numerical evaluation of hereditary integrals, we employ a fast convolution method [2] that reduces the memory cost to O(log(N)) and the computational complexity to O(N log(N)). Furthermore, we combine the fast convolution with high-order backward differentiation to achieve third-order time integration accuracy. We confirm that in 3D viscoelastic simulations, the integer order models strongly depends on the relaxation parameters, while the fractional order models are less sensitive. As an application to long-time simulations in complex geometries, we also apply the method to modeling fluid-structure interaction of a 3D patient-specific compliant cerebral artery with an aneurysm. Taken together, our findings demonstrate that fractional calculus can be employed effectively in modeling complex behavior of materials in realistic 3D time-dependent problems if properly designed efficient algorithms are employed to overcome the extra memory requirements and computational complexity associated with the non-local character of fractional derivatives.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

یافته های آنژیوگرافی در آنوریسم داخل جمجمه ای، بیمارستان امام، 79-1374

Background: This investigation was conducted in order to study angiographic findings in patients with cerebral aneurysm. Materials and Methods: The study conducted on 136 cases of ruptured cerebral aneurysms between 1995-2000 confirmed by means of 4-vessel cerebral angiography to get an insight to racial, geographic and environmental factors predisposing to the occurrence of subarachnoid hemorr...

متن کامل

Role of matrix metalloproteinases (MMPs) and MMP inhibitors on intracranial aneurysms: a review article

 Cerebrovascular disease is one of the leading causes of death in the world, and about one-fourth of cerebrovascular deaths are due to ruptured cerebral aneurysms (CA). Hence it is important to find a way to reduce aneurysm formation and its subsequent morbidity and mortality. Proteolytic activity capable of lysing gelatin has been shown to be increased in aneurysm tissue and expressio...

متن کامل

Fractional Calculus Applied to Model Arterial Viscoelasticity

−− Arterial viscoelasticity can be described using stress-relaxation experiments. To fit these curves, models with springs and dashpots, based on differential equations, were widely studied. However, uniaxial tests in arteries show particular shapes with an initial steep decay and a slow asymptotic relaxation. Recently, fractional order derivatives were used to conceive a new component called s...

متن کامل

Diagnostic accuracy of magnetic resonance angiography for cerebral aneurysms in correlation with 3D-digital subtraction angiographic images: a study of 133 aneurysms.

BACKGROUND AND PURPOSE We investigated the sensitivity of 3D-time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity. METHODS 3D-TOF MRA was performed in 82 patie...

متن کامل

Diagnostic Accuracy of Magnetic Resonance Angiography for Cerebral Aneurysms in Correlation With 3D–Digital Subtraction Angiographic Images

Background and Purpose—We investigated the sensitivity of 3D–time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity. Methods—3D-TOF MRA was performed in 82 patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of computational physics

دوره 323  شماره 

صفحات  -

تاریخ انتشار 2016