A novel method for the assessment of the accuracy of computing laminar flow stroke volumes using a real-time 3D ultrasound system: In vitro studies.

نویسندگان

  • Xiaokui Li
  • Muhammad Ashraf
  • Karl Thiele
  • Aarti Hejmadi Bhat
  • Ron Sakaguchi
  • John C Mitchell
  • Julie A Brie
  • Monica Young
  • Rima S Bader
  • James Pemberton
  • David J Sahn
چکیده

AIMS Laminar flow stroke volume (SV) quantification in the ascending aorta or pulmonary artery can provide a measure for determining cardiac output (CO). Comparing flows across different valves can also compute shunt volumes and regurgitant fractions. Quantification methods for 3D color Doppler laminar flow volumes have been developed using reconstructive 3D, but these are cumbersome and time-consuming both in acquisition and measurement. Our study evaluated newly developed color Doppler mapping with real-time live 3D echo to test velocity, spatial and temporal resolution for computing SV. METHODS AND RESULTS Five rubber tubes (diameters=3.0, 2.25, 2.0, 1.9, 1.7 cm), a freshly dissected porcine aorta (Ao) and a pulmonary artery (PA) (both 2-3 cm diameter) were connected to a pulsatile pump in a water bath. Different SV, from 10 to 80 ml/beat, were studied at pump rates of 40-60 bpm in this phantom model with flow quantified by timed collection. The Nyquist limit was set between 43 and 100 cm/s and frame rate ranged from 14 to 23/s. ECG triggered 3D color Doppler volumes were acquired with a 2-4 MHz probe. The digital scan line data from the 3D volumes, with retained velocity assignments, was exported and analyzed offline by MatLab custom software. Close correlations were found between 3D calculated SV and reference data for all tubes (r=0.98, y=1.14x-1.69, SEE=2.82 ml/beat, p<0.0001). Both Ao and PA flows were also highly correlated with the reference measurements (PA: r=0.98, SEE=3.17 ml/beat; Ao: r=0.99, SEE=3.20 ml/beat). CONCLUSIONS Real-time 3D color Doppler method could provide an efficient, accurate and reliable method for clinical evaluation and quantification of flow volumes in patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Solution of Reacting Laminar Flow Heat and Mass Transfer in Ducts of Arbitrary Cross-Sections for Newtonian and Non-Newtonian Fluids

This study is concerned with the numerical analysis, formulation, programming and computation of steady, 3D conservation equations of reacting laminar flow heat and mass transfer in ducts of arbitrary cross-sections. The non-orthogonal boundary-fitted coordinate transformation method is applied to the Cartesian form of overall-continuity, momenta, energy and species-continuity equations, parabo...

متن کامل

The Solution of Laminar Incompressible Flow Equation with Free Surfaces in Curvilinear Coordinates

In this paper a novel numerical approach is presented for solving the transient incompressible fluid flow problems with free surfaces in generalized two-dimensional curvilinear coordinate systems. Solution algorithm is a combination of implicit real-time steps and explicit pseudo-time steps. Governing fluid flow equations are discretized using a collocated finite-volume mesh. Convective terms a...

متن کامل

The Solution of Laminar Incompressible Flow Equation with Free Surfaces in Curvilinear Coordinates

In this paper a novel numerical approach is presented for solving the transient incompressible fluid flow problems with free surfaces in generalized two-dimensional curvilinear coordinate systems. Solution algorithm is a combination of implicit real-time steps and explicit pseudo-time steps. Governing fluid flow equations are discretized using a collocated finite-volume mesh. Convective terms a...

متن کامل

Incompressible laminar flow computations by an upwind least-squares meshless method

In this paper, the laminar incompressible flow equations are solved by an upwind least-squares meshless method. Due to the difficulties in generating quality meshes, particularly in complex geometries, a meshless method is increasingly used as a new numerical tool. The meshless methods only use clouds of nodes to influence the domain of every node. Thus, they do not require the nodes to be conn...

متن کامل

Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 2005