Influence of environmental changes on integrating radon detectors: results of an intercomparison exercise.
نویسندگان
چکیده
An intercomparison exercise for passive integrating radon detectors has been carried out with the participation of 12 detection systems from 10 laboratories. The detection systems comprise three commonly used in radon integrating measurements, tracks, activated charcoal canisters and electrets. The exposures were carried out in the radon and thoron chambers at the Institute of Energy Techniques (INTE) of the Technical University of Catalonia (UPC), which is considered to be the Spanish reference chamber. The detectors were exposed to three different temperatures (10, 20 and 30 degrees C) and relative humidities (30, 45 and 80%). Furthermore, in three exposures radon concentration was drastically changed during the exposure period in order to study the efficiency of canister collection. The results indicated that only the charcoal canister response was found to be significantly influenced by external climatic conditions and radon fluctuations. Those track detectors, which are unable to measure thoron concentrations show thoron sensitivity and thus interfere with precise measurement of radon. Detectors for measuring thoron concentration show quite a different response, which could be related to their traceability.
منابع مشابه
Intercomparison of radon CR-39 detector systems conducted in CLOR’s calibration chamber
Within the framework of the grant of the Polish Ministry of Science and Higher Education entitled Seasonal changes of indoor radon (222Rn) concentrations of Poland (N506 1127 33) radon laboratories united in the Radon Center – the Non-governmental International Scientific Network – perform measurements of radon concentration in houses located in various areas of Poland. These laboratories belon...
متن کاملInternational Intercomparison Exercise on Natural Radiation Measurements under Field Conditions (ifc11)
One of the aims of the First Intercomparison on Natural Radioactivity Under Field Conditions was to test different instruments and detectors for the measurement of radon gas and external gamma radiation (dose rate) in filed conditions, where the levels of natural radiation are quite high. The event was organized by the Radon group of University of Cantabria, (Spain) LaRUC, and was held in the e...
متن کاملIntercomparison of retrospective radon detectors.
We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in dire...
متن کاملInvestigating Indoor Radon Concentration Using CR-39 Detector; a Case Study of Gachin Dwellings in Hormozgan
Introduction: Radon is a colorless inert gas which decay products are the main component of natural radioactive elements that are naturally produced in under layers of earth crust by decay of radium and uranium. It enters through buildings via gaps and cracks. Radon gas decay products like alpha particle can increase the incidence of lung cancer in human. Since every person sp...
متن کاملMeasurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector
The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiation protection dosimetry
دوره 123 4 شماره
صفحات -
تاریخ انتشار 2007