The associations between cardiometabolic risk factors and visceral fat measured by a new dual-energy X-ray absorptiometry-derived method in lean healthy Caucasian women

نویسندگان

  • Tomasz Miazgowski
  • Barbara Krzyżanowska-Świniarska
  • Joanna Dziwura-Ogonowska
  • Krystyna Widecka
چکیده

Excess visceral adipose tissue (VAT) is associated with a cluster of metabolic abnormalities. A new dual-energy X-ray absorptiometry (DXA)-based VAT measurement approach, CoreScan™, computes VAT mass and volume within the android region of a total body DXA scan. However, there have been no reference values developed for this method. The objective of this study was to determine the normal reference ranges for DXA-derived VAT in young, healthy, premenopausal women. We also sought associations between VAT, blood lipids, glucose, insulin and insulin resistance. In 120 randomly selected, normal weight, Caucasian women aged 20-40 years, we measured body fat (BF), VAT and lean mass by DXA. We also assessed blood pressure, waist and hip circumference, waist-to-hip ratio, body mass index, fasting glucose, insulin, triglycerides (TG), and high- (HDL) and low-density lipoproteins. Insulin resistance was evaluated by the homeostasis model assessment (HOMA). VAT mass accounted for 0.37 ± 0.3 % of weight and 1.11 ± 0.72 % of BF. Mean VAT mass and volume were 235.9 ± 183 g (95 % CI 202.7-269.1) and 250.3 ± 194.5 cm(3) (95 % CI 215.1-285.4), respectively. Anthropometric indices moderately correlated with VAT. VAT significantly correlated with HDL (R = -0.193; P = 0.03), glucose (R = 0.252; P = 0.005) and HOMA (R = 0.184; P = 0.049). In this study, we provide normal values of VAT mass and volume measured by DXA and determined for healthy, normal weight, Caucasian women aged 20-40 years. Even in such strictly selected population VAT correlated positively with insulin resistance and inversely with HDL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Utility and Reproducibility of Visceral Adipose Tissue Measurements Derived from Dual-energy X-ray Absorptiometry in White and African American Adults

OBJECTIVE The purpose of this study was to determine reproducibility and clinical thresholds for DXA-derived visceral adipose tissue (VAT). DESIGN AND METHODS The sample included 2317 white and African American adults 18-74 years of age. VAT areas (cm(2) ) were measured using a Hologic DXA scanner equipped with APEX 4.0 software. Reproducibility was assessed using repeated measurements on 101...

متن کامل

Visceral adipose tissue measured by DXA correlates with measurement by CT and is associated with cardiometabolic risk factors in children.

BACKGROUND Visceral adipose tissue (VAT) generally demonstrates a stronger relationship with cardiometabolic risk factors than total body fat or subcutaneous adipose tissue. OBJECTIVES The purpose of this study was to compare VAT estimated in children by total volume dual-energy X-ray absorptiometry (DXA) with a gold standard measurement, single slice (L4-L5) computed tomography (CT). METHO...

متن کامل

Different Associations of Trunk and Lower-Body Fat Mass Distribution with Cardiometabolic Risk Factors between Healthy Middle-Aged Men and Women

The aim of this study was to assess whether the gender-specific pattern of fat mass (FM) distribution is related to gender differences in cardiometabolic risk factors. 207 healthy middle-aged Japanese were included in the study. We measured FM in the total body, trunk, and lower-body with dual-energy X-ray absorptiometry (DXA). The percentage of trunk FM (TFM) and lower-body FM (LFM) is noted a...

متن کامل

Visceral fat reference values derived from healthy European men and women aged 20-30 years using GE Healthcare dual-energy x-ray absorptiometry

Dual energy X-ray absorptiometry (DXA) is an established technique used in clinical and research settings to evaluate total and regional fat. Additionally, recently developed software allow to quantify visceral adipose tissue (VAT). Currently, there are no reference values available for GE Healthcare DXA systems for VAT. The aim of this study was to develop reference values for VAT in healthy E...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2014