Radiation injuries after fluoroscopic procedures.
نویسندگان
چکیده
Fluoroscopically guided diagnostic and interventional procedures have become much more commonplace over the last decade. Current fluoroscopes are easily capable of producing dose rates in the range of 0.2 Gy (20 rads) per minute. The dose rate often changes dramatically with patient positioning and size. Most machines currently in use have no method to display approximate patient dose other than the rough surrogate of total fluoroscopy time. This does not include patient dose incurred during fluorography (serial imaging or cine runs), which can be considerably greater than dose during fluoroscopy. There have been over 100 cases of documented radiation skin and underlying tissue injury, a large portion of which resulted in dermal necrosis. The true number of injuries is undoubtedly much higher. The highest dose procedures are complex interventions such as those involving percutaneous angioplasties, stent placements, embolizations, and TIPS. In some cases skin doses have been in excess of 60 Gy (6000 rads). In many instances the procedures have been performed by physicians with little training in radiation effects, little appreciation of the radiation injuries that are possible or the strategies that could have been used to reduce both patient and staff doses. Almost all of the severe injuries that have occurred were avoidable.
منابع مشابه
CASE STUDY Chronic radiodermatitis following cardiac catheterisation: a report of two cases and a brief review of the literature
Cardiac angiography produces one of the highest radiation exposures of any commonly used diagnostic x ray procedure. Recently, serious radiation induced skin injuries have been reported after repeated therapeutic interventional procedures using prolonged fluoroscopic imaging. Two male patients, aged 62 and 71 years, in whom chronic radiodermatitis developed one to two years after two consecutiv...
متن کاملReducing Radiation Exposure in an Electrophysiology Lab with Introduction of Newer Fluoroscopic Technology
The use of fluoroscopic devices exposes patients and operators to harmful effects of ionizing radiation in an electrophysiology (EP) lab. We sought to know if the newer fluoroscopic technology (Allura Clarity) installed in a hybrid EP helps to reduce prescribed radiation dose. We performed radiation dose analysis of 90 patients who underwent various procedures in the EP lab at a community teach...
متن کاملChronic radiodermatitis following cardiac catheterisation: a report of two cases and a brief review of the literature.
Cardiac angiography produces one of the highest radiation exposures of any commonly used diagnostic x ray procedure. Recently, serious radiation induced skin injuries have been reported after repeated therapeutic interventional procedures using prolonged fluoroscopic imaging. Two male patients, aged 62 and 71 years, in whom chronic radiodermatitis developed one to two years after two consecutiv...
متن کاملCT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists.
PURPOSE To determine the radiation dose to radiologists who perform computed tomographic (CT) fluoroscopic interventional procedures by using a quick-check method and a low-milliampere technique. MATERIALS AND METHODS Two hundred twenty CT fluoroscopy--guided interventional procedures were performed in 189 patients. Procedures included 57 spinal injections, 17 spinal biopsies, 24 chest biopsi...
متن کاملComparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
BACKGROUND Percutaneous vertebroplasty (PV) requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes) during PV can provide simultaneous two-planar projections with reducing operative time. However, the two-fluoroscopic technique may expose...