Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.
نویسندگان
چکیده
Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodilution (CO(TD)) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of which three had shunt flow through areas without significant gas exchange, the mean difference (bias) and limits of agreement (+/- 2 S.D.) were 0.6 +/- 1.2 litre x min(-1) when comparing CO(FICK) and Q(EP), and -0.8 +/- 1.3 litre x min(-1) when comparing CO(FICK) and CO(TD). When correction for intrapulmonary shunt flow was applied (i.e. calculation of CO(RB)) in all 11 patients, the bias between CO(FICK) and CO(RB) was 0.1 +/- 0.9 litre x min(-1), primarily because agreement improved in the three patients with significant shunt flow. In the eight patients without significant shunt flow, the agreement between Q(EP) and CO(FICK) was 0.3 +/- 0.9 litre x min(-1). In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output as did thermodilution. In the absence of significant shunt flow, measurement of Q(EP) itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method available to a larger group of clinicians working with patients with cardiovascular diseases.
منابع مشابه
The reliability of noninvasive cardiac output measurement using the inert gas rebreathing method in patients with advanced heart failure.
BACKGROUND Impaired cardiac output (CO) is a key element of heart failure (HF). So far, there has been no simple, reliable, inexpensive and non-invasive CO measurement method feasible for clinical practice. Not a single diagnostic test has been elaborated to diagnose and monitor HF. The aim of the study was the evaluation of the reliability of a new, non-invasive CO measurement device utilizing...
متن کاملNon-invasive measurement of pulmonary blood flow during prone positioning in patients with early acute respiratory distress syndrome.
In the daily clinical routine at the bedside, information on effective pulmonary blood flow (PBF) is limited and requires invasive monitoring, including a pulmonary artery catheter, to determine both cardiac output and intrapulmonary shunt. Therefore we evaluated a non-invasive method for the measurement of PBF in a clinical setting, including 12 patients with acute respiratory failure (acute r...
متن کاملAccuracy and Reliability of Non-invasive Cardiac Output: The Future in Cardiology?
A new generation of non-invasive cardiac output monitors provides an alternative to using conventional invasive methods such as thermodilution and direct Fick. The Bioz.com measures changes in thoracic electrical bioimpedance (TEB) of the descending aorta. The Innocor uses the principle of inert gas rebreathing. Simultaneous TEB and thermodilution cardiac output measurements were taken from 27 ...
متن کاملValidation of Noninvasive Measurement of Cardiac Output Using Inert Gas Rebreathing in a Cohort of Patients With Heart Failure and Reduced Ejection Fraction.
BACKGROUND Cardiac output (CO) is a key indicator of cardiac function in patients with heart failure. No completely accurate method is available for measuring CO in all patients. The objective of this study was to validate CO measurement using the inert gas rebreathing (IGR) method against other noninvasive and invasive methods of CO quantification in a cohort of patients with heart failure and...
متن کاملEvaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics
Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria. Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical science
دوره 102 2 شماره
صفحات -
تاریخ انتشار 2002