Quinary excitation method for pulse compression ultrasound measurements.

نویسندگان

  • D M J Cowell
  • S Freear
چکیده

A novel switched excitation method for linear frequency modulated excitation of ultrasonic transducers in pulse compression systems is presented that is simple to realise, yet provides reduced signal sidelobes at the output of the matched filter compared to bipolar pseudo-chirp excitation. Pulse compression signal sidelobes are reduced through the use of simple amplitude tapering at the beginning and end of the excitation duration. Amplitude tapering using switched excitation is realised through the use of intermediate voltage switching levels, half that of the main excitation voltages. In total five excitation voltages are used creating a quinary excitation system. The absence of analogue signal generation and power amplifiers renders the excitation method attractive for applications with requirements such as a high channel count or low cost per channel. A systematic study of switched linear frequency modulated excitation methods with simulated and laboratory based experimental verification is presented for 2.25 MHz non-destructive testing immersion transducers. The signal to sidelobe noise level of compressed waveforms generated using quinary and bipolar pseudo-chirp excitation are investigated for transmission through a 0.5m water and kaolin slurry channel. Quinary linear frequency modulated excitation consistently reduces signal sidelobe power compared to bipolar excitation methods. Experimental results for transmission between two 2.25 MHz transducers separated by a 0.5m channel of water and 5% kaolin suspension shows improvements in signal to sidelobe noise power in the order of 7-8 dB. The reported quinary switched method for linear frequency modulated excitation provides improved performance compared to pseudo-chirp excitation without the need for high performance excitation amplifiers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Ultrasonic Imaging Speckle Supression and Contrast Enhancement Technique by Means of Frequency Compounding and Coded Excitation

A method for improving the contrast resolution of B-mode images is proposed by combining the speckle reduction technique of frequency compounding (FC), and the coded excitation and pulse compression technique called resolution enhancement compression (REC). FC suppresses speckle but at the expense of a reduction in axial resolution. Using REC the axial resolution and bandwidth of the imaging sy...

متن کامل

Ultrasound Elasticity Imaging System with Chirp-Coded Excitation for Assessing Biomechanical Properties of Elasticity Phantom

The biomechanical properties of soft tissues vary with pathological phenomenon. Ultrasound elasticity imaging is a noninvasive method used to analyze the local biomechanical properties of soft tissues in clinical diagnosis. However, the echo signal-to-noise ratio (eSNR) is diminished because of the attenuation of ultrasonic energy by soft tissues. Therefore, to improve the quality of elastograp...

متن کامل

Quadratic Frequency Modulated Thermal Wave Imaging for Non-destructive Testing

Thermal non-destructive testing and evaluation of glass fibre reinforced plastic materials has gained more importance in aerospace industry due to low weight and high strength capabilities in severe environmental conditions. More recently, pulse compression favorable non-stationary excitation schemes have been exhibiting reliable defect detection capabilities in infrared non-destructive testing...

متن کامل

Small Lesion Detection with Resolution Enhancement Compression: a Method of Coded Excitation/pulse Compression by Paul Mitchell Linden

A novel coded excitation method, resolution enhancement compression (REC), increases the axial resolution and the echo signal-to-noise ratio (eSNR) for an ultrasonic imaging system. The REC technique was examined for its ability to improve lesion detectability. In addition to lesion detectability, the REC technique was examined in the context of being peak voltage limited or peak pressure limit...

متن کامل

Improved shear wave motion detection using coded excitation for transient elastography

Transient elastography (TE) is well adapted for use in studying liver elasticity. However, because the shear wave motion signal is extracted from the ultrasound signal, the weak ultrasound signal can significantly deteriorate the shear wave motion tracking process and make it challenging to detect the shear wave motion in a severe noise environment, such as within deep tissues and within obese ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasonics

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 2008