Laser beam quality and pointing measurement with an optical resonator.
نویسندگان
چکیده
We present a compact diagnostic breadboard that is based on an optical ring resonator for measuring beam quality and pointing of single-frequency continuous wave lasers at a wavelength of 1064 nm. To determine the beam quality of the coherent test beam, this optical resonator is used to perform a mode decomposition into Hermite-Gaussian modes. For our laser system, a power fraction in the fundamental Gaussian mode of 97.2%+/-0.2% was measured. Residual misalignment and mis-mode-matching to the resonator as well as the astigmatism and/or ellipticity of the test beam have been determined. Numerical simulations showed that measurements of the M(2) factor and transversal intensity distribution are not suitable for determining this power fraction. To measure the beam pointing, the fundamental mode of the optical resonator was used as a stable reference. The pointing of the test beam was measured with the differential wave front sensing technique up to Fourier frequencies of 1 kHz with a sensitivity to relative pointing of /epsilon/=1x10(-6)/sqrt[Hz]. Pointing measurements with an alternative method were performed and showed good agreement.
منابع مشابه
Automatic laser beam characterization of monolithic Nd:YAG nonplanar ring lasers.
A detailed beam characterization of continuous-wave single-frequency Nd:YAG solid-state ring lasers at a wavelength of 1064 nm is presented. The power noise, frequency noise, beam pointing fluctuations, spatial beam quality, and other properties of eight lasers of the same model were measured with a compact diagnostic instrument based on an optical ring resonator. One of the eight lasers was au...
متن کاملبررسی عددی کیفیت پرتویی لیزر قرص نازک با تشدیدگر ناپایدار
In this article, M2 factor of a thin disk laser with unstable resonator in two regimes is calculated numerically. In the first case, thermal effects are ignored and the parameters of beam width, divergence angle, radius of wave front curvature and finally, M2 factor of laser beam are calculated by using generalized beam parameters. These calculations show that the beam quality of the laser is d...
متن کاملMeasuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry
Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...
متن کاملUnified Pulsed Laser Range Finder and Velocimeter using Ultra-Fast Time-To-Digital Converter
In this paper, we present a high accuracy laser range finder and velocimeter using ultra-fast time-to-digital converter (TDC). The system operation is based on the measuring the round-trip time of a narrow laser pulse. A low-dark current high-speed PIN photodiode is used to detect the triggered laser beam and to produce start signal. The pulsed laser diode generates 45W optical power at 30ns du...
متن کاملHigh pulse energy and symmetrical far field from an optical parametric oscillator in the red spectral range
Remote sensing applications often require high energy laser-like beams with narrow bandwidth and low divergence at wavelengths that cannot be reached directly with ordinary laser materials. The common way of generating such wavelengths is through optical parametric oscillators (OPOs), sumor difference frequency generators, or a combination of these. For the new beam to be generated with high co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 78 7 شماره
صفحات -
تاریخ انتشار 2007