An evaluation of a novel instrument for measuring macular pigment optical density: the MPS 9000.

نویسندگان

  • James Loughman
  • Grainne Scanlon
  • John M Nolan
  • Veronica O'Dwyer
  • Stephen Beatty
چکیده

PURPOSE Of the antioxidants found in the human retina, only the macular carotenoid quantities can be estimated noninvasively (albeit in a collective fashion), thus facilitating study of their role in that tissue. The aim of this study was to evaluate concordance between macular pigment optical density (MPOD) values recorded on a commercially available instrument, the MPS 9000, with those of an already validated heterochromatic flicker photometry instrument. Also, we assessed and compared test-retest variability for each instrument. METHODS Macular pigment optical density at 0.5 retinal eccentricity was measured using two different heterochromatic flicker photometers, the MPS 9000 and the Macular Densitometer(TM), in 39 healthy subjects. Test-retest variability was evaluated separately for each instrument by taking three readings over a 1-week period in 25 subjects. RESULTS There was a moderate positive correlation for MPOD at 0.5° of retinal eccentricity between the MPS 9000 and the Macular Densitometer described by the linear equation y = 0.763x + 0.172 (r = 0.68, p < 0.001, r(2) = 0.46); however, a paired-samples t-test showed a significant difference in terms of mean values, with a bias of lower MPOD values being yielded by the MPS 9000 (t = -4.103, p < 0.001). Bland-Altman analysis indicated only moderate agreement between the two instruments, reflected in 95% limits of agreement of 0.1 ± 0.27. Inter-sessional repeatability, expressed as a coefficient of repeatability, ranged from 0.18 to 0.21 [mean (±SD): 0.19 (0.02)] for the MPS 9000 and from 0.11 to 0.12 [mean (±SD): 0.12 (0.01)] for the Macular Densitometer. CONCLUSION The results demonstrate that the MPS 9000 consistently yields MPOD readings, which are lower than that found with the Macular Densitometer, and exhibits substantial test-retest variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A portable instrument for measuring macular pigment with central fixation.

PURPOSE To evaluate the reliability and validity of a portable instrument for measuring macular pigment optical density. METHODS The instrument is small, uses light emitting diodes as light sources and the principles of heterochromatic flicker photometry of comparing foveal and extra-foveal minimum flicker matches. It uses central fixation for the extra-foveal matches, which subjects found ea...

متن کامل

A new desktop instrument for measuring macular pigment optical density based on a novel technique for setting flicker thresholds.

A rapid portable technique for estimating macular pigment optical density (MPOD) in large populations is described. The new instrument utilises a novel method for setting flicker thresholds which is undemanding for naïve and elderly observers and easily operated by a non-technical person. The method has good repeatability (r = 0.97) and the data are comparable with an optical method based on re...

متن کامل

(Abstract for AAO Meeting 2014) Variations of macular pigment optical density with axial length and foveal choroidal thickness in young Hong Kong Chinese

Forty-five healthy Chinese adults, aged 18-33 years old, were recruited. All subjects were free from color vision deficiency and ocular abnormalities. MPOD was determined by Macular Pigment Screener (MPS II, Elektron Technology) using standard test mode. AL was measured by IOL Master (Carl Zeiss Meditec). ChT was determined by manual segmentation of the retinal images from spectral-domain optic...

متن کامل

The relationship between foveal short-wavelength-sensitive visual function and macular pigment optical density in the ageing age

To investigate the role of macular pigment in preserving foveal short-wavelength-sensitive (SWS) visual function in the ageing eye orientation identification acuity was measured in the fovea and at 12° eccentricity (nasal visual field) under SWS-cone isolating conditions in 73 participants (aged 20-71). Macular pigment optical density (MPOD) was measured at 0.5° eccentricity from the foveal cen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta ophthalmologica

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2012