A New Implementation of a Multiport Automatic Network Analyzer
نویسندگان
چکیده
A generalized multiport network analyzer implemented using commercially available hardware is presented. Measurement calibration is accomplished through a novel calibration procedure which requires only conventional standards used for two-port calibrations, The calibration theory accounts for the errors due to the signal switching network but does not systematically remove errors due to signal leakage between port pairs. The approach is verified on a three-port test set implementation, and the measuring system can be expanded to n-ports with additional hardware in a straightforward manner. Experimental verification was carried out through measurement of one, two, and three ports devices connected to the test set ports in several different ways. Excellent agreement of the same corrected S-parameters measured at different test set ports was observed, and confidence in system accuracy is established through measurement of two-port verification standards.
منابع مشابه
Pic Microcontroller-Based Automatic Meter Reading (AMR) System Using the Low Voltage (LV) Power Line Network (TECHNICAL NOTE)
Automatic Meter Reading (AMR) is the remote collection of consumption data from customer’s utility meters over telecommunications, radio, power line and other links. AMR provides water, electric and gas utility service companies the opportunity to streamline metering, billing and collection activities, increase operational efficiency and improve customer service. The AMR system consists of thre...
متن کاملAutomatic implementation of a new recovery coefficient for Reliable contour milling
In contour milling, to render the machining process more automated with significant productivity without remaining material after machining, a new recovery coefficient was developed. The coefficient was inserted in the computation of contour parallel tool paths to fix the radial depth of cut in the way to ensure an optimized overlap area between the passes in the corners, without residuals. Thu...
متن کاملA Reliable and Economically Feasible Automatic Meter Reading System Using Power Line Distribution Network (TECHNICAL NOTE)
Automatic Meter Reading (AMR) is the remote collection of consumption data from customer’s utility meters over telecommunications, radio, power line and other links. AMR provides water, electric and gas utility−service companies the opportunities to streamline metering, billing and collection activities, increase operational efficiency and improve customer service. Utility company uses technolo...
متن کاملDesign and Implementation of a Kalman Filter-Based Time-Varying Harmonics Analyzer
Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...
متن کاملA multi-scale convolutional neural network for automatic cloud and cloud shadow detection from Gaofen-1 images
The reconstruction of the information contaminated by cloud and cloud shadow is an important step in pre-processing of high-resolution satellite images. The cloud and cloud shadow automatic segmentation could be the first step in the process of reconstructing the information contaminated by cloud and cloud shadow. This stage is a remarkable challenge due to the relatively inefficient performanc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015