Ion Mobility-Derived Collision Cross Section As an Additional Measure for Lipid Fingerprinting and Identification
نویسندگان
چکیده
Despite recent advances in analytical and computational chemistry, lipid identification remains a significant challenge in lipidomics. Ion-mobility spectrometry provides an accurate measure of the molecules' rotationally averaged collision cross-section (CCS) in the gas phase and is thus related to ionic shape. Here, we investigate the use of CCS as a highly specific molecular descriptor for identifying lipids in biological samples. Using traveling wave ion mobility mass spectrometry (MS), we measured the CCS values of over 200 lipids within multiple chemical classes. CCS values derived from ion mobility were not affected by instrument settings or chromatographic conditions, and they were highly reproducible on instruments located in independent laboratories (interlaboratory RSD < 3% for 98% of molecules). CCS values were used as additional molecular descriptors to identify brain lipids using a variety of traditional lipidomic approaches. The addition of CCS improved the reproducibility of analysis in a liquid chromatography-MS workflow and maximized the separation of isobaric species and the signal-to-noise ratio in direct-MS analyses (e.g., "shotgun" lipidomics and MS imaging). These results indicate that adding CCS to databases and lipidomics workflows increases the specificity and selectivity of analysis, thus improving the confidence in lipid identification compared to traditional analytical approaches. The CCS/accurate-mass database described here is made publicly available.
منابع مشابه
High resolution ion mobility-mass spectrometry for separation and identification of isomeric lipids.
Lipidomics is a particularly difficult analytical challenge due to the number and importance of isomeric species that are known or postulated in biological samples. Current separation and identification techniques are too often insufficiently powerful, slow or ambiguous. High resolution, low field ion mobility coupled to mass spectrometry is shown here to have sufficient performance to represen...
متن کاملIon Mobility Derived Collision Cross Sections to Support Metabolomics Applications
Metabolomics is a rapidly evolving analytical approach in life and health sciences. The structural elucidation of the metabolites of interest remains a major analytical challenge in the metabolomics workflow. Here, we investigate the use of ion mobility as a tool to aid metabolite identification. Ion mobility allows for the measurement of the rotationally averaged collision cross-section (CCS),...
متن کاملConformational Ordering of Biomolecules in the Gas Phase: Nitrogen Collision Cross Sections Measured on a Prototype High Resolution Drift Tube Ion Mobility-Mass Spectrometer
Ion mobility-mass spectrometry measurements which describe the gas-phase scaling of molecular size and mass are of both fundamental and pragmatic utility. Fundamentally, such measurements expand our understanding of intrinsic intramolecular folding forces in the absence of solvent. Practically, reproducible transport properties, such as gas-phase collision cross-section (CCS), are analytically ...
متن کاملFundamentals of ion mobility spectrometry.
Fundamental questions in ion mobility spectrometry have practical implications for analytical applications in general, and omics in particular, in three respects. (1) Understanding how ion mobility and collision cross section values depend on the collision gas, on the electric field and on temperature is crucial to ascertain their transferability across instrumental platforms. (2) Predicting co...
متن کاملCollision cross section calibrants for negative ion mode traveling wave ion mobility-mass spectrometry.
Unlike traditional drift-tube ion mobility-mass spectrometry, traveling-wave ion mobility-mass spectrometry typically requires calibration in order to generate collision cross section (CCS) values. Although this has received a significant amount of attention for positive-ion mode analysis, little attention has been paid for CCS calibration in negative ion mode. Here, we provide drift-tube CCS v...