Estimation of the Biodynamic Responses Distributed at Fingers and Palm Based on the Total Response of the Hand-Arm System

نویسندگان

  • Ren G. Dong
  • Subhash Rakheja
  • Thomas W. McDowell
  • Daniel E. Welcome
  • John Z. Wu
چکیده

The major objective of this study is to develop a modelling method for estimating the biodynamic responses distributed at the fingers and the palm of the hand based on the total driving-point mechanical impedance of the entire hand-arm system. A five degrees-of-freedom (DOF) model with a set of constraints proposed in this study was used in the estimation. Three sets of mechanical impedance data measured at the fingers and palm of the hand were used to examine the validity of the proposed method. The estimated response distributed at the palm was consistent with the measured data even when the real part of the impedance alone was used in the modeling (coefficient of correlation, r 2 ≥ 0.902). Better agreements between the estimated and measured responses were obtained (r 2 ≥ 0.929) when the magnitude and phase of the total impedance or the magnitude alone were used in the modeling estimation. In each case, the estimated response distributed at the fingers was also reliably correlated with the experimental data (r 2 ≥ 0.726) but it was not as consistent with the experimental data as that distributed at the palm was. The applications of the proposed method were also demonstrated using five other sets of reported experimental data. This study also demonstrated that the modeling method may also be used to assess the quality of the experimental data in some cases. As a special application of the acceptable data identified in this study, this study also defined a 2-DOF model for the construction of a hand-arm simulator for tool tests. The results of this study and the proposed modelling method are expected to contribute to the revision of the ISO 10068 (1998). Relevance to industry Prolonged exposure to intensive tool vibration could cause hand-arm vibration syndrome (HAVS). An effective approach to reduce the HAVS is to reduce the intensity of the vibration exposure. The proposed modelling method and the results of this study can be used to help

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of biodynamic forces distributed on the fingers and the palm exposed to vibration.

The hand-tool coupling force in the operation of a vibrating tool is generally composed of applied force (AF) and biodynamic force (BF). There is wide interest in quantifying the coupling force. The objectives of this study are to develop an effective method for estimating the BF and to investigate its fundamental characteristics. Using the biodynamic response of the hand-arm system, such as ap...

متن کامل

استفاده از برآورد حالت‌های پویای دست مبتنی بر مدل، برای تقلید عملکرد بازوی انسان توسط ربات با داده‌های کینکت

Pose estimation is a process to identify how a human body and/or individual limbs are configured in a given scene. Hand pose estimation is an important research topic which has a variety of applications in human-computer interaction (HCI) scenarios, such as gesture recognition, animation synthesis and robot control. However, capturing the hand motion is quite a challenging task due to its high ...

متن کامل

Frequency weightings based on biodynamics of fingers-hand-arm system.

The frequency weighting for assessing hand-transmitted vibration exposure is critical to obtaining a true dose-response relationship. Any valid weighting must have a solid theoretical foundation. The objectives of this study are to examine the biodynamic foundation for assessing the vibration exposure and to develop a set of biodynamic methods to formulate the frequency weightings for different...

متن کامل

Biodynamic response at the palm of the human hand subjected to a random vibration.

This study investigated the biodynamic response (BR) distributed at the palm of the hand subjected to a random vibration. Twelve male subjects were used in the experiment. Each subject applied three coupling actions (grip-only, push-only, and combined grip and push) on a simulated tool handle at three different levels (50, 75, and 100 N) of palm force. This study found that the hand-arm system ...

متن کامل

اندازه گیری گشتاور لازم برای بازکردن درب شیشه های دهان پهن و ارتباط آن با ویژگی های آنتروپومتریک و فیزیولوژیک مؤثر

Introduction: Nine percent of all available packaging are jars with steel lids. However, some consumers have trouble with jar opening. The aim of the current research was to analyze the exerting force on jar lids regarding the torque input to the anthropometric and physiological characteristics of the consumers. Methods: In this study, the force distributed on the fingers and the palm was ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011