Quantitative simultaneous Tc/ I cardiac SPECT using MC-JOSEM

نویسندگان

  • Jinsong Ouyang
  • Xuping Zhu
  • Cathryn M. Trott
  • Georges El Fakhri
چکیده

Simultaneous rest Tc-Sestamibi / I-BMIPP cardiac SPECT imaging has the potential to replace current clinical Tc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is difficult, however, because their emission energies are close. The authors previously developed a fast Monte Carlo MC -based joint ordered-subset expectation maximization JOSEM iterative reconstruction algorithm MC-JOSEM , which simultaneously compensates for scatter and cross talk as well as detector response within the reconstruction algorithm. In this work, the authors evaluated the performance of MC-JOSEM in a realistic population of Tc / I studies using cardiac phantom data on a Siemens e.cam system using a standard cardiac protocol. The authors also compared the performance of MC-JOSEM for estimation tasks to that of two other methods: standard OSEM using photopeak energy windows without scatter correction NSCOSEM and standard OSEM using a Compton-scatter energy window for scatter correction SCOSEM . For each radionuclide the authors separately acquired high-count projections of radioactivity in the myocardium wall, liver, and soft tissue background compartments of a water-filled torso phantom, and they generated synthetic projections of various dual-radionuclide activity distributions. Images of different combinations of myocardium wall/background activity concentration ratios for each radionuclide were reconstructed by NSC-OSEM, SC-OSEM, and MC-JOSEM. For activity estimation in the myocardium wall, MC-JOSEM always produced the best relative bias and relative standard deviation compared with NSC-OSEM and SC-OSEM for all the activity combinations. On average, the relative biases after 100 iterations were 8.1% for Tc and 3.7% for I with MC-JOSEM, 39.4% for Tc and 23.7% for I with NSC-OSEM, and 20.9% for Tc with SC-OSEM. The relative standard deviations after 30 iterations were 0.7% for Tc and 1.0% for I with MC-JOSEM, as compared to 1.1% for Tc and 1.2% for I with NSC-OSEM and 1.3% for Tc with SC-OSEM. Finally, the authors compared the relative standard deviation after 30 iterations with the minimum theoretical variance on activity estimation, the Cramer–Rao lower bound CRB , and with the biased CRB. The measured precision was larger than the biased bound values by factors of 2–4, suggesting that further improvement could be made to the method. © 2009 American Association of Physicists in Medicine. DOI: 10.1118/1.3063544

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved activity estimation with MC-JOSEM versus TEW-JOSEM in 111In SPECT.

We have previously developed a fast Monte Carlo (MC)-based joint ordered-subset expectation maximization (JOSEM) iterative reconstruction algorithm, MC-JOSEM. A phantom study was performed to compare quantitative imaging performance of MC-JOSEM with that of a triple-energy-window approach (TEW) in which estimated scatter was also included additively within JOSEM, TEW-JOSEM. We acquired high-cou...

متن کامل

Optimisation of Simultaneous Tl-201/Tc-99m Dual Isotope Reconstruction with Monte-Carlo-Based Scatter Correction

Simultaneous Tl-201/Tc-99m dual isotope myocardial perfusion SPECT is seriously hampered by down-scatter from Tc-99m into the Tl-201 energy window. This paper presents and optimises the ordered-subsets-expectation-maximisation-(OS-EM-) based reconstruction algorithm, which corrects the down-scatter using an efficient Monte Carlo (MC) simulator. The algorithm starts by first reconstructing the T...

متن کامل

Simultaneous Tc-99m and I-123 dual-radionuclide imaging with a solid-state detector-based brain-SPECT system and energy-based scatter correction

BACKGROUND A brain single-photon emission computed tomography (SPECT) system using cadmium telluride (CdTe) solid-state detectors was previously developed. This CdTe-SPECT system is suitable for simultaneous dual-radionuclide imaging due to its fine energy resolution (6.6 %). However, the problems of down-scatter and low-energy tail due to the spectral characteristics of a pixelated solid-state...

متن کامل

Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector

OBJECTIVES The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the effec...

متن کامل

Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Simultaneous acquisition of dual-isotope SPECT data offers a number of advantages over separately acquired data; however, simultaneous acquisition can result in cross-contamination between isotopes. In this work we propose and evaluate two frameworks for iterative model-based compensation of cross-contamination in dual-isotope SPECT. The methods were applied to cardiac imaging with technetium-9...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009