Five-year outcomes of chronic total occlusion treatment with a biolimus A9-eluting biodegradable polymer stent versus a sirolimus-eluting permanent polymer stent in the LEADERS all-comers trial.
نویسندگان
چکیده
BACKGROUND Few data are available on long-term follow-up of drug-eluting stents in the treatment of chronic total occlusion (CTO). The LEADERS CTO sub-study compared the long-term results in CTO and non-CTO lesions of a Biolimus A9™-eluting stent (BES) with a sirolimus-eluting stent (SES). METHODS Among 1,707 patients enrolled in the prospective, multi-center, all-comers LEADERS trial, 81 with CTOs were treated with either a BES (n = 45) or a SES (n = 36). The primary endpoint was the occurrence of major adverse cardiac events (MACE): cardiac death, myocardial infarction (MI) and clinically-indicated target vessel revascularization (TVR). RESULTS At 5 years, the rate of MACE was numerically higher in the CTO group than in the non-CTO group (29.6% vs. 23.3%; p = 0.173), with a significant increase in the incidence of target lesion revascularization (TLR) (21.0 vs. 12.6; p = 0.033), but no difference in stent thrombosis (ST). Patients with CTO receiving a BES demonstrated a lower incidence of MACE (22.2% vs. 38.9%; p = 0.147) with a significant reduction in TLR compared to patients receiving a SES (11.1% vs. 33.3%, p = 0.0214) with an incidence similar to that observed in the non-CTO group treated with BES (11.6%). Definite ST at 5 years nearly halved in the BES group (4.4% vs. 8.3%, p = 0.478) with no ST in the BES group after the first year (0% vs. 8.3%, p for interaction = 0.009). CONCLUSIONS The use of a BES showed a reduction in MACE, TVR, TLR, and ST over time in the CTO subset with similar outcome as for non-CTO lesions.
منابع مشابه
The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
AIMS The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). METHODS AND RESULTS One thousand seven hundred and seven patients were randomised to unrestricted...
متن کاملBiolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.
BACKGROUND Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS This randomised, ...
متن کاملImplantation of the biodegradable polymer biolimus-eluting stent in patients with high SYNTAX score is associated with decreased cardiac mortality compared to a permanent polymer sirolimus-eluting stent: two year follow-up results from the "all-comers" LEADERS trial.
BACKGROUND The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the "all-comers" LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by ...
متن کاملComparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.
AIMS Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has l...
متن کامل2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
OBJECTIVES This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. BACKGROUND BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegrada...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiology journal
دوره 23 6 شماره
صفحات -
تاریخ انتشار 2016