An evaluation of in-plane shields during thoracic CT.

نویسندگان

  • S J Foley
  • M F McEntee
  • L A Rainford
چکیده

The object of this study was to compare organ dose and image quality effects of using bismuth and barium vinyl in-plane shields with standard and low tube current thoracic CT protocols. A RANDO phantom was scanned using a 64-slice CT scanner and three different thoracic protocols. Thermoluminescent dosemeters were positioned in six locations to record surface and absorbed breast and lung doses. Image quality was assessed quantitatively using region of interest measurements. Scanning was repeated using bismuth and barium vinyl in-plane shields to cover the breasts and the results were compared with standard and reduced dose protocols. Dose reductions were most evident in the breast, skin and anterior lung when shielding was used, with mean reductions of 34, 33 and 10 % for bismuth and 23, 18 and 11 % for barium, respectively. Bismuth was associated with significant increases in both noise and CT attenuation values for all the three protocols, especially anteriorly and centrally. Barium shielding had a reduced impact on image quality. Reducing the overall tube current reduced doses in all the locations by 20-27 % with similar increases in noise as shielding, without impacting on attenuation values. Reducing the overall tube current best optimises dose with minimal image quality impact. In-plane shields increase noise and attenuation values, while reducing anterior organ doses primarily. Shielding remains a useful optimisation tool in CT and barium is an effective alternative to bismuth especially when image quality is of concern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

Evaluation of polyurethane composite shields effect on reducing the risk of cataract induction at head CT scan

Head computed tomography is a common diagnostic examination, which may cause lenticular opacity and cataracts. Cataract induction is one of the non-stochastic effects of radiation, that happens at threshold dose of 0.5 Gy. Recent studies illustrate that only irradiation to the sensitive (germinative) zone of the lens is a prerequisite to cataract development. Recently, the dose values absorbed ...

متن کامل

Unusual Presentation of Pulmonary Hematoma after Blunt Chest Wall Trauma

A 25-year-old man was admitted in hospital due to right side hemopneumothorax secondary to car accident. A chest tube was inserted. During the hospitalization days, chest CT scan revealed a 3cmx3 cm oval-shaped density located in the right upper lobe. Since he was in a good general condition, he was discharged from hospital after removal of chest tube and a follow-up chest CT-scan was recommend...

متن کامل

Comparing X-ray dose reduction capability of silicon-bismuth micro- and nanocomposite shields using chest CT test

Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...

متن کامل

Designing and construction of breast shields using silicone composite of Bismuth for chest CT

Background: Bismuth composites are new and non-lead shields that are capable of breast dose reduction while preserving image quality. In this study, different percentages of Bismuth were used in designing and constructing polymer composites as breast shields in chest CT.  Materials and Methods: Micro particles of Bismuth with a ratio of 1% to 15% in Silicone matrix with two thicknesses were use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 155 4  شماره 

صفحات  -

تاریخ انتشار 2013