Measurement of arterial input functions for dynamic susceptibility contrast magnetic resonance imaging using echoplanar images: comparison of physical simulations with in vivo results.
نویسندگان
چکیده
Measurement of the arterial input bolus shape is essential to the quantification of mean transit time and blood flow with dynamic susceptibility contrast (DSC) MRI. Input functions derived from the echoplanar signal intensity within or near arteries are highly nonlinear, yet such input functions are widely used. We employed a physical model for the echoplanar signal intensity from an artery as a function of contrast agent concentration, artery size, and angle to the magnetic field to test approaches for the measurement of the arterial input function. The simulated results confirmed the strong nonlinearity of signal in the neighborhood of vessels. Of the input function measurement methods considered, the simulations suggested that measurement of signal near but not within a large vessel is most accurate, but mean transit times (MTT) calculated with these input functions are highly sensitive to peak bolus concentration. Input functions determined from voxels demonstrating the shortest first moment overestimated the MTT but the measured MTTs were more robust to changes in peak concentration. Characteristics of the measured in vivo input functions were consistent with the simulations. Our results emphasize the important contribution of input function errors to the uncertainty in MTT and blood flow imaging with DSC MRI.
منابع مشابه
Comparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei
Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...
متن کاملAn Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors
Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملFe3O4@Ag Nanoprobe for Detection of Ovarian Cancer Cell Line Using Magnetic Resonance Imaging
Background and Aims: Magnetic resonance imaging (MRI) plays an essential role in molecular imaging by delivering the contrast agent into targeted cells. The aim of this study was to evaluate the use of magnetic nanoparticles containing iron oxide and silver (Fe3O4@Ag core-shell nanoprobe) as a contrast agent for the detection of ovarian cancer cell line ovcar-3. Materials and Methods: Co-preci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 55 3 شماره
صفحات -
تاریخ انتشار 2006