Fast Fourier‐based simulation of off‐resonance artifacts in steady‐state gradient echo MRI applied to metal object localization

نویسندگان

  • Frank Zijlstra
  • Job G. Bouwman
  • Ieva Braškutė
  • Max A. Viergever
  • Peter R. Seevinck
چکیده

PURPOSE To accelerate simulation of off-resonance artifacts in steady-state gradient echo MRI by using fast Fourier transforms and demonstrate its applicability to metal object localization. THEORY AND METHODS By exploiting the repetitive nature of steady-state pulse sequences it is possible to use fast Fourier transforms to calculate the MR signal. Based on this principle, a method for fast simulation of off-resonance artifacts was designed. The method was validated against Bloch simulations and MRI scans. Its clinical relevance was demonstrated by employing it for template matching-based metal object localization, as applied to a titanium cylinder, an oxidized zirconium knee implant, and gold fiducials. RESULTS The fast simulations were accurate compared with actual MRI scans of the objects. The differences between the fast simulations and Bloch simulations were minor, while the acceleration scaled linearly with the number of phase-encoding lines. The object localization method accurately localized the various metal objects. CONCLUSION The proposed simulation methodology provided accurate 3D simulations of off-resonance artifacts with a lower computational complexity than Bloch simulations. The speed of the simulations opens up possibilities in image reconstructions involving off-resonance phenomena that were previously infeasible due to computational limitations, as demonstrated for metal object localization. Magn Reson Med 78:2035-2041, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Reduction of Susceptibility Artifacts in MRI using Narrowband Excitation

Introduction Off-resonance effects related to susceptibility differences in objects are a major headache in gradient-echo imaging techniques. They lead to intra-voxel dephasing during the delay time between excitation and reception (TE), resulting in signal drop-outs. In addition, phase accumulation during the acquisition leads to image artifacts, which are particularly severe in fast imaging t...

متن کامل

FMRI using high flip-angle alternating steady state balanced SSFP supported by Monte Carlo studies

Introduction The need exists for a functional MRI (fMRI) technique capable of artifact-free whole brain coverage, with good blood oxygenation level dependent (BOLD) contrast to noise ratio (CNR), and high temporal resolution. Conventional gradient echo (GRE) BOLD fMRI suffers from signal dropout in regions of magnetic field inhomogeneity, limiting coverage, while spin echo fMRI has reduced BOLD...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

Flow compensation in non-balanced SSFP

Introduction. Non-balanced steady-state free precession sequences (SSFP-FID and SSFP-echo) are gradient-spoiled pulse sequences that provide high signal even in presence of long T1 values, because the transverse magnetization is not completely incoherent by means of radiofrequency spoiling. Contrary to balanced SSFP sequences they do not suffer from off-resonance banding artifacts, making them ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 78  شماره 

صفحات  -

تاریخ انتشار 2017