"Unbound analog" radioimmunoassays for free thyroxin measure the albumin-bound hormone fraction.

نویسندگان

  • J R Stockigt
  • V Stevens
  • E L White
  • J W Barlow
چکیده

We have assessed the influence of albumin-bound thyroxin (T4) on apparent free T4 values obtained by two "unbound analog" free T4 methods (AmerlexR Free T4 and Clinical Assays one-step Free T4). We evaluated sera showing three different albumin anomalies: total hereditary analbuminemia, partially corrected analbuminemia, and familial dysalbuminemic hyperthyroxinemia, where abnormal albumin-binding of analog tracer is associated with high apparent free T4 values by these methods. In hereditary analbuminemia, free T4 was almost undetectable by both assays; in contrast, free T4 by equilibrium dialysis was normal. After addition of T4-free human serum albumin, the apparent free T4 concentration in total hereditary analbuminemia became normal by the analog methods. Immunoprecipitation of [125I]T4 and the unidentified labeled kit analogs by antiserum to human albumin was negligible in untreated total hereditary analbuminemia and approximately twice normal in familial dysalbuminemic hyperthyroxinemia. Therefore, alterations in tracer binding to albumin correlate with the apparent free T4 concentrations obtained by the analog methods. The interactions of the unidentified analog tracers and T4 with albumin are such that these techniques principally reflect the albumin-bound T4 moiety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electroimmunoassay of prealbumin in cerebrospinal fluid.

10. Amino N, Nishi K, Nakatani K, et al. Effect of albumin concentration on the assay of serum free thyroxin by equilibrium radioimmunoassay with labeled thyroxin analog (Amerlex#{174} F’reeT4). Clin C/tern 29, 321-325 (1983). 11. Stockigt JR, Stevens V, White EL, Barlow JW. “Unbound analog” radioimmunoassay methods for free thyroxin measure the albumin-bound hormone fraction. Clin C/tern 29, 1...

متن کامل

Effect of detergent on triglyceride assay.

2. Meinhold H, Wenzel KW. Comparative methodological studies with six commercial FF4 kits. Nucl Compact 1985;16:317-20. 3. Ross HA. An indirect assay for serum free thyroxin (FF4) using monoclonal antibody coated tubes and radiolabeled thyroxin. Ibid., 1985;32:314-6. 4. Stockigt JR, Stevens V, White EL, Barlow JW. “Unbound analog” radioimmunoassays for free thyroxin measure the albuminbound hor...

متن کامل

Comprehensive study of a thyroxin-analog-based assay for free thyroxin ("Amerlex FT4").

The basic theory of thyroxin-analog-based radioimmunoassays for free thyroxin has been extended to evaluate definitively the effects arising from residual binding of the tracer analog to serum proteins. Using experimentally determined binding constants and computer simulation techniques, we studied the effects of thyroxin-analog binding to serum proteins on results of Amerlex FT4 radioimmunoass...

متن کامل

Chemically blocked analog assays for free thyronines. II. Use of equilibrium dialysis to optimize the displacement by chemical blockers of T4 analog and T3 analog from albumin while avoiding displacement of T4 and T3 from thyroxin-binding globulin.

Chemical blockers used to displace thyronine analog from albumin in analog kits for assay of free thyroxin (FT4) or free triiodothyronine (FT3) may also displace thyroxin (T4) or triiodothyronine (T3) from thyroxin-binding globulin (TBG), resulting in an apparent TBG dependence of results of free hormone estimates. We used equilibrium dialysis and antibody binding to assess the displacement of ...

متن کامل

One-step immunoassays for free (unbound) hormones: the effects of tracer binding by serum proteins.

In binding assays for determination of free (non-protein-bound) hormones in serum or plasma, the influence of the measuring system on the original analyte concentration in the sample must be considered. In one- or single-step free-hormone immunoassays, the labeled analyte or analog-tracer not only is bound to the antibody, it also is bound, to some extent, to serum proteins. The dependence of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 7  شماره 

صفحات  -

تاریخ انتشار 1983