Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China
نویسندگان
چکیده
BACKGROUND To evaluate the distribution of biometric parameters and corneal astigmatism using the IOLMaster device before phacoemulsification in cataract patients in Central China. METHODS Consecutive cataract patients were recruited at the Central Hospital of Wuhan between January 2015 and June 2016. Ocular axial length (AL), keratometry values, anterior chamber depth (ACD) and horizontal corneal diameter (white to white [WTW]) of each cataract-affected eye were measured with the IOLMaster device. RESULTS The study evaluated 3209 eyes of 2821 cataract patients. The mean AL, ACD, and WTW were 24.38 ± 2.47 mm, 3.15 ± 0.48 mm, and 11.63 ± 0.43 mm, respectively. Corneal astigmatism of 0.51-1.00 diopters (D) was the most common range of values (34.96%). A total of 10.56% patients exhibited a corneal astigmatism greater than 2.0 D. The flat and steep keratometry values gradually increased with age. The mean ACD and WTW showed increasing trends as the AL increased (P < 0.001). When the AL was shorter than 26.0 mm, the keratometry decreased as AL increased. The against-the-rule (ATR) astigmatism proportion increased with age and the with-the-rule (WTR) astigmatism proportion decreased with age. CONCLUSIONS The profile of ocular biometric data and corneal astigmatism may help ophthalmologists improve their surgical procedures and make an appropriate IOL choice to gain a high quality of postoperative vision.
منابع مشابه
Factors Influencing Efficacy of Peripheral Corneal Relaxing Incisions during Cataract Surgery
Purpose. To evaluate influencing factors on the residual astigmatism after performing peripheral corneal relaxing incisions (PCRIs) during cataract surgery. Methods. This prospective study included patients who were scheduled for cataract surgery with PCRIs. Optical biometry (IOLMaster 500, Carl Zeiss Meditec AG, Germany) was taken preoperatively, 1 week, 4 months, and 1 year postoperatively. A...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملThe Ocular Biometry of Adult Cataract Patients on Lifeline Express Hospital Eye-Train in Rural China
Aims. To describe and explore the distribution of ocular biometric parameters of adult cataract patients in rural China. Methods. Three Lifeline Express Hospital Eye-Train missions of Peking University People's Hospital in China were chosen. 3828 adult cataract patients aged 29 to 88 years with axial length (AL) less than 27.0 mm were enrolled. The ocular biometry including visual acuity (VA), ...
متن کاملLimbal Relaxing Incision during Phacoemulsification for the Correction of Astigmatism
.................................. Purpose: To determine the difference in mean post-operative astigmatism of patients having limbal relaxing incisions with phacoemulsification as compared to phacoemulsification alone for the correction of pre-existing corneal astigmatism. Material and Methods: This study was conducted in the Civil Hospital Karachi Eye Unit II, from 1 st December 2009 1 st Dece...
متن کاملPrevalence of Corneal Astigmatism in Patients before Cataract Surgery in Northern China
Purpose. To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates in a teaching hospital in northern China. Methods. From May 1, 2012, to April 30, 2013, partial coherence interferometry (IOLMaster) measurements of all qualified cataract surgery candidates were retrospectively collected and analyzed. Results. The study evaluated 12,449 eyes from ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2017