Effect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma

نویسندگان

  • Naveed Nilforushan
  • Mohammad Parsamanesh
  • Fei Yu
  • Nariman Nassiri
  • Arezoo Miraftabi
  • Anne L. Coleman
چکیده

PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinted Acrysof Natural IOL was performed in 16 eyes of 16 patients with visually significant cataract (best-corrected visual acuity (VA) better than 20/120) and mild to moderate glaucoma. Pre- and postoperative values for VA and for perimetry indices including mean deviation (MD), pattern standard deviation (PSD), and foveal threshold (FT) from both SAP and SWAP testing were compared. RESULTS Postoperative VA improved significantly after cataract surgery and yellow-tinted IOL implantation (P < 0.001). After cataract extraction and IOL implantation, MD and FT on SWAP testing improved significantly (P = 0.001); however, there was no statistically significant change with SAP testing between the pre- and postoperative perimetry indices. There was no statistically significant change in PSD with either SAP or SWAP testing postoperatively. The differences between pre- and postoperative values for all perimetry indices under study were not significant when comparing SAP with SWAP tests, except for MD which had improved statistically significantly in SWAP testing (P = 0.03). CONCLUSIONS In mild to moderate glaucoma patients with cataracts, the perimetry indices of SWAP testing improved after phacoemulsification and yellow-tinted IOL implantation. This suggests that the yellow-tinted IOLs have less effect on SWAP testing than visually significant cataracts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry.

PURPOSE To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spher...

متن کامل

Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...

متن کامل

Short-wavelength automated perimetry and standard perimetry in the detection of progressive optic disc cupping.

OBJECTIVE To compare progression in short-wavelength automated perimetry (SWAP) and white-on-white (standard) perimetry in eyes with progressive glaucomatous changes of the optic disc detected by serial stereophotographs. METHODS Forty-seven glaucoma patients with at least 2 disc stereophotographs more than 2 years apart, along with standard perimetry and SWAP examinations within 6 months of ...

متن کامل

[Sensitivity of size I stimulus in achromatic automated perimetry for detection of glaucomatous visual field defects: a comparative analysis with short wavelength automated perimetry and standard automated perimetry (SITA)].

PURPOSE To compare sensitivity and specificity of achromatic perimetry with size I stimulus (WW-I) with standard automated perimetry (SITA strategy) and blue on yellow perimetry (SWAP) for early diagnosis of glaucoma. METHODS Seventy-three eyes of 73 suspects, glaucomatous and normal subjects underwent automated perimetry with SITA 24-2, WW-I and SWAP. After application of specific criteria o...

متن کامل

The Effect of Yellow Tinted Intraocular Lenses on the Result of Frequency Doubling Perimetry after Cataract Surgery

PURPOSE To investigate the effect of yellow tinted intraocular lenses (IOLs), implanted in the bag after phacoemulsification, on the result of frequency doubling technique (FDT) perimetry. METHODS For 68 eyes of 52 patients, an IOL was implanted in the bag after phacoemulsification. The patients were categorized into three groups according to the type of implanted IOLs used. IOLs were selecte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2014