Is 25Hz enough to accurately measure a dynamic change in the ocular accommodation?
نویسندگان
چکیده
BACKGROUND Accommodation is often recorded at a low sampling rate using devices such as autorefractors that are designed to measure the static refractive error. It is therefore important to determine if that resolution is sufficient to accurately measure the dynamic properties of accommodation. The current study provides both theoretical and empirical evidence on the ideal sampling rate necessary to measure a dynamic response. METHODS Accommodative and disaccommodative step stimuli ranging from 1-3D (1D steps) were presented using a Badal optical system. Responses from 12 children (8-13 years) and 6 adults (20-35 years) were recorded using a dynamic photorefractor (DPR). Fast Fourier transformation was applied to the unsmoothed dynamic responses including position, velocity and acceleration. Also, velocity and acceleration main sequence (MS) characteristics were compared between three photorefractor conditions on 3 subjects. RESULTS The Nyquist sampling limit necessary to accurately estimate position, velocity and acceleration was at least 5, 10 and 70Hz, respectively. Peak velocity and acceleration were significantly underestimated at a lower rate (p<0.5). However, the slope of MS remained invariant with sampling rate (p>0.5). CONCLUSION Contrary to the previous findings, a dynamic accommodative response exhibited frequencies larger than 10Hz. Stimulus direction and amplitude had no influence on the frequencies present in the dynamic response. Peak velocity and acceleration can be significantly underestimated when sampled at a lower rate. Taken as a whole, low sampling rate instruments can accurately estimate static accommodation, however, caution needs to be exercised when using them for dynamic accommodation.
منابع مشابه
Evaluation of ocular accommodation, convergence and fusional vergence changes during Ramadan
Purpose: There are a few researches regarding the effects of Islamic fasting on visual system. The aim of this study was to investigate the effects of Ramadan fasting on the amplitude of accommodation (AA), near point of convergence (NPC), positive and negative fusional vergences (PFV and NFV, respectively) in visually healthy fasters. Methods: AA, NPC, PFV and NFV at far (6m) and near (40cm) w...
متن کاملDynamic DEA: A Hybrid Measure Approach
In the real world applications, there are some situations where inputs and outputs are time-dependent and are affected during the production periods. Capital stock can be seen as an effective instance in such occasions. In order to handling long-time planning, dynamic structure was proposed in efficiency evaluation. In this framework, there are some of the inputs and outputs change proportiona...
متن کاملDevelopment of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients
Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...
متن کاملInverse Maximum Dynamic Flow Problem under the Sum-Type Weighted Hamming Distance
Inverse maximum flow (IMDF), is among the most important problems in the field ofdynamic network flow, which has been considered the Euclidean norms measure in previousresearches. However, recent studies have mainly focused on the inverse problems under theHamming distance measure due to their practical and important applications. In this paper,we studies a general approach for handling the inv...
متن کاملMeasuring the temperature dependence of refractive index in water phantom for precise monitoring of the absorbed dose by radiation therapy techniques
In this paper, an experimental setup is used to measure the temperature dependence of the refractive index of a water phantom. In radiation calorimetry by laser beams and interferometric systems, the amount of change induced by radiation within the phantom can be accurately measured. Absorption of dose and the resulted change in temperature changes the refractive index within the material. In o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of optometry
دوره شماره
صفحات -