In-situ measurement of reactive hydrocarbons at Hohenpeissenberg with comprehensive two-dimensional gas chromatography (GC×GC-FID): use in estimating HO and NO3
نویسنده
چکیده
During a field campaign at the Meteorological Observatory Hohenpeissenberg (MOHp) in July 2004, volatile organic compounds (VOCs) were measured using comprehensive two-dimensional gas chromatography (GC×GC). Comparison to routinely made gas chromatography mass spectrometry (GC-MS) measurements showed good agreement for a variety of anthropogenic and biogenic ambient VOCs ranging in concentration from below the detection limit (0.1 pmol mol−1) to 180 pmol mol−1. Pronounced diurnal cycles were found for both the biogenic and anthropogenic compounds, driven for the most part by the daily rise and fall of the boundary layer over the station. For the reactive compounds (lifetimes <2 days), a significant, non-zero dependency of the variability on lifetime was found, indicating that chemistry (as opposed to transport alone) was playing a role in determining the ambient VOC concentrations. The relationship was exploited using a single-variate analysis to derive a daytime mean value of HO (5.3±1.4×106 molecules cm−3), which compares well to that measured at the site, 3.2±2.3×106 molecules cm−3. The analysis was extended to the night time data to estimate concentrations for NO3 (1.47±0.2×108 molecules cm−3), which is not measured at the site. The feasibility of this approach for environments dominated by emissions of shortlived VOCs to estimate ambient levels of radical species is discussed. Correspondence to: J. Williams ([email protected])
منابع مشابه
Measurement of VOCs with GCxGC-FID: estimating HO + NO3
In-situ measurement of reactive hydrocarbons at Hohenpeissenberg with comprehensive gas chromatography (GCxGC-FID): use in estimating HO and NO3 S. Bartenbach, J. Williams, C. Plass-Dülmer, H. Berresheim, and J. Lelieveld Max-Planck-Institute for Chemistry, J.J. Becher Weg 27, 55128 Mainz, Germany Deutscher Wetterdienst, Meteorologisches Observatorium Hohenpeissenberg, Albin-Schwaiger-Weg 10, 8...
متن کاملComprehensive two-dimensional gas chromatography (GC×GC) measurements of volatile organic compounds in the atmosphere
During the MINOS campaign in August 2001 comprehensive two-dimensional gas chromatography (GC×GC) was applied to the in situ measurements of atmospheric volatile organic compounds (VOCs) at the Finokalia ground station, Crete. The measurement system employs a thermal desorption unit for on-line sampling and injection, and a GC×GC separation system equipped with a flame ionization detector (FID)...
متن کاملDevelopment and Validation of a GC-FID Method for Diagnosis of Methylmalonic Acidemia
Background: Urinary organic acids are water-soluble intermediates and end products of the metabolism of amino acids, carbohydrates, lipids, and a number of other metabolic processes. In the hereditary diseases known as organic acidurias, an enzyme or co-factor defect in a metabolic pathway leads to the accumulation and increased excretion of one or more of these acidic metabolites. Gas chromato...
متن کاملQualitative mass spectrometric analysis of the volatile fraction of creosote-treated railway wood sleepers by using comprehensive two-dimensional gas chromatography.
The volatile composition of 20-year-old out-of-service creosote-treated railway wood sleepers was studied. The emitted volatile fraction was collected by means of dynamic purge-and-trap concentration at ambient temperature, and analyzed by comprehensive two-dimensional gas chromatography (GC x GC) hyphenated with mass spectrometric detection systems, using quadrupole (GC x GC/qMS) and time-of-f...
متن کاملDevelopment of a Precise Method for the Quantitative Analysis of Hydrocarbons Using Post−Column Reaction Capillary Gas Chromatography with Flame Ionization Detection
Gas chromatographs equipped with flame ionization detectors (GC/FID) are widely used for the quantitative analysis of hydrocarbon compounds. For precise quantitative analysis, it is essential to calibrate the GC/FID system using calibration standards for each analyte. This is both inefficient and cost−prohibitive. The response factor method is also used for calibration of the GC/FID. The respon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006