Shape from Water: Bispectral Light Absorption for Depth Recovery

نویسندگان

  • Yuta Asano
  • Yinqiang Zheng
  • Ko Nishino
  • Imari Sato
چکیده

This paper introduces a novel depth recovery method based on light absorption in water. Water absorbs light at almost all wavelengths whose absorption coefficient is related to the wavelength. Based on the Beer-Lambert model, we introduce a bispectral depth recovery method that leverages the light absorption difference between two nearinfrared wavelengths captured with a distant point source and orthographic cameras. Through extensive analysis, we show that accurate depth can be recovered irrespective of the surface texture and reflectance, and introduce algorithms to correct for nonidealities of a practical implementation, including tilted light source and camera placement and nonideal bandpass filters. We construct a coaxial bispectral depth imaging system using low-cost off-the-shelf hardware and demonstrate its use for recovering the shapes of complex and dynamic objects in water. Experimental results validate the theory and practical implementation of this novel depth recovery paradigm, which we refer to as shape from water.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تأثیر استفاده از مانیتورینگ شاخص دوطیفی (Bispectral index (BIS)) بر ریکاوری و عوارض بعد از عمل در بیماران تحت عمل جراحی سزارین

Background and Aim: Anesthesia has several side effects which are different based on the type of surgery, medication, and depth of anesthesia. The present study aimed at identifying the effect of bi-spectral index monitoring on recovery and postoperative complications in caesarean. Materials and Methods: In this double-blinded clinical trial study with control group, 68 women who were candidate...

متن کامل

The optimal anesthetic depth for interventional neuroradiology: comparisons between light anesthesia and deep anesthesia

BACKGROUND This study was designed to determine the optimal anesthetic depth for the maintenance and recovery in interventional neuroradiology. METHODS Eighty-eight patients undergoing interventional neuroradiology were randomly allocated to light anesthesia (n = 44) or deep anesthesia (n = 44) groups based on the value of the bispectral index (BIS). Anesthesia was induced with propofol, alfe...

متن کامل

Measuring surface water in soil with light reflectance

The light absorbed by water in soil and plants is readily determined using hyperspectral full-range imagery and field spectrometers. The full absorption of light can be accounted for by fitting the shape of water absorptions at the same time as other diagnostic bands using multiple Gaussian functions. This research is particularly important in soils due to the loss of mineral band depth with th...

متن کامل

Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.

BACKGROUND Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. METHODS Patients und...

متن کامل

Engineering of core/shell nanoparticles surface plasmon for increasing of light penetration depth in tissue (modeling and analysis)

Objectives: In this article, a new procedure for increasing the light penetration depth in a tissue is studied and simulated. It has been reported that the most important problem in biomedical optical imaging relates to the light penetration depth, and so this makes a dramatic restriction on its applications. In the optical imaging method, the detection of the backscattered pho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016