Formation and Fluorimetric Characterization of Micelles in a Micro-flow Through System with Static Micro Mixer

نویسندگان

  • Michael Schuch
  • G. Alexander Gross
  • J. Michael Köhler
چکیده

The formation and behaviour of micelles of sodium dodecylsulfate in water byuse of a static micro mixer were studied. Trisbipyridylruthenium(II) was applied asindicator dye, 9-methylanthracene was used for fluorescence quenching. All experimentswere carried out by a micro fluid arrangement with three syringe pumps, a 2 1 two-stepstatic micro mixer (IPHT Jena) and a on-line micro fluorimetry including a luminescencediode for excitation, a blue glass filter (BG 7, Linos), two edge filters (RG 630, Linos) anda photo counting module (MP 900, Perkin Elmer). It was possible to measure thefluorescence inside the PTFE tube (inner diameter 0.5 mm) directly. A linear dependenceof fluorescence intensity from dye concentration was observed in absence of quencher andsurfactant as expected. An aggregation number of about 62 was found in the flow raterange between 300 and 800 μL/min. The fluorescence intensity increases slightly, butsignificant with increasing flow rate, if no quencher is present. In the presence of quencher,the fluorescence intensity decreases with decreasing surfactant concentration and withenhanced flow rate. The strength of the flow rate effect on the fluorescence increases withdecreasing surfactant concentration. The size of micelles was determined in micro channelsby the micro fluorimetric method in analogy to the conventional system. The micellesextract the quencher from the solution and lower, this way, the quenching effect. The sizeof micelles was estimated and it could be shown, that the flow rate has only low effect onthe aggregation number at the investigated flow rates. The effect of flow rate andsurfactant concentration on the fluorescence in the presence of quencher was interpreted asa shift in the micelle concentration due to the shear forces. It is expected, that thefluorescence intensity is lowered, if more quencher molecules are molecular disperse distributed inside the solution. Obviously, the lowered fluorescence intensity at higher flow rates suggests a reduction of the micelle density causing an increase of quencher concentration outside the micelles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating Fluid Mixing in Electro-Osmotic Flow Through Passive Micro-Mixers Having Square and Triangle Barriers

Objective: In this article, a numerical study is conducted on mixing of two fluids in the liquid phase with two different concentrations of a chemical species in the electro-osmotic flow. Methods: The base liquid is an electrolyte which flows in a two-dimensional micro-channel having electrically charged walls. Lorentz electric force, which is used as stimulating flow factor, is created by appl...

متن کامل

Investigating Fluid Mixing in Electro-Osmotic Flow Through Passive Micro-Mixers Having Square and Triangle Barriers

Objective: In this article, a numerical study is conducted on mixing of two fluids in the liquid phase with two different concentrations of a chemical species in the electro-osmotic flow. Methods: The base liquid is an electrolyte which flows in a two-dimensional micro-channel having electrically charged walls. Lorentz electric force, which is used as stimulating flow factor, is created by appl...

متن کامل

Numerical Investigation of Fluid Mixing in a Micro-Channel Mixer with Two Rotating Stirrers by Using the Incompressible SPH Method

Fluid mixing is a crucial and challenging process for microfluidic systems, which are widely used in biochemical processes. Because of their fast performance, active micromixers that use stirrer blades are considered for biological applications. In the present study, by using a robust and convenient Incompressible Smoothed Particle Hydrodynamics (ISPH) method, miscible mix...

متن کامل

Rapid mixing of Newtonian and non-Newtonian fluids in a three-dimensional micro-mixer using non-uniform magnetic field

The mixing of Newtonian and non-Newtonian fluids in a magnetic micro-mixer was studied numerically using  ferrofluid. The mixing process was performed in a three-dimensional steady-state micro-mixer. A magnetic source was mounted at the entrance of the micro-channel to oscillate the magnetic particles. The effects of electric current, inlet velocity, size of magnetic particles, and non-Newtonia...

متن کامل

Analysis of Motion of Micro-Gripper Exposed to the Electric Field and Thermal Stresses for Using in Micro-Robotics

Micro system technology is a relatively new scientific research that deals with the development and study of properties of materials in micro dimensions. Micro-grippers are widely used in switching, positioning, and assembling micron sized components in micro-robotics. In this study, the static and dynamic behavior of visco-elastic Micro-Tweezers under the thermal and electrostatic field is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2007