Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study

نویسندگان

  • Antonius Pizanis
  • Jörg H Holstein
  • Felix Vossen
  • Markus Burkhardt
  • Tim Pohlemann
چکیده

BACKGROUND Anterior bone grafts are used as struts to reconstruct the anterior column of the spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses and compromise further healing. Despite the different stabilizing techniques that have evolved, from posterior or anterior fixating implants to combined anterior/posterior instrumentation, graft pseudarthrosis rates remain an important concern. Furthermore, the need for additional anterior implant fixation is still controversial. In this bench-top study, we focused on the graft-bone interface under various conditions, using two simulated spinal injury models and common surgical fixation techniques to investigate the effect of implant-mediated compression and contact on the anterior graft. METHODS Calf spines were stabilised with posterior internal fixators. The wooden blocks as substitutes for strut grafts were impacted using a "pressfit" technique and pressure-sensitive films placed at the interface between the vertebral bone and the graft to record the compression force and the contact area with various stabilization techniques. Compression was achieved either with posterior internal fixator alone or with an additional anterior implant. The importance of concomitant ligament damage was also considered using two simulated injury models: pure compression Magerl/AO fracture type A or rotation/translation fracture type C models. RESULTS In type A injury models, 1 mm-oversized grafts for impaction grafting provided good compression and fair contact areas that were both markedly increased by the use of additional compressing anterior rods or by shortening the posterior fixator construct. Anterior instrumentation by itself had similar effects. For type C injuries, dramatic differences were observed between the techniques, as there was a net decrease in compression and an inadequate contact on the graft occurred in this model. Under these circumstances, both compression and the contact area on graft could only be maintained at high levels with the use of additional anterior rods. CONCLUSIONS Under experimental conditions, we observed that ligamentous injury following type C fracture has a negative influence on the compression and contact area of anterior interbody bone grafts when only an internal fixator is used for stabilization. Because of the loss of tension banding effects in type C injuries, an additional anterior compressing implant can be beneficial to restore both compression to and contact on the strut graft.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

معرفی اولین مورد استئوبلاستوما در دنیا با گرفتاری سه بدنه مهره مجاور به همراه پاراپلژی اسپاستیک کامل و اسکولیوز

A thirteen years old girl was referred for back pain and right thoracic scoliosis, complete spastic paraplegia, bladder and bowel incontinence . The patient had history of back pain for a 4 year period eventually leading to scoliosis and neurological deficiency. Symptoms gradually worsened up to 4 months before admission converting to complete spastic paraplegia and bladder and bowel incontinen...

متن کامل

Evaluation of Role of Anterior Debridement and Decompression of Spinal Cord and Instrumentation in Treatment of Tubercular Spondylitis

STUDY DESIGN Prospective study with simple randomization. PURPOSE To evaluate the results of anterior spinal instrumentation, debridement and decompression of cord and compare it with results of a similar procedure done without the use of anterior instrumentation. OVERVIEW OF LITERATURE Use of anterior spinal instrumentation in treatment of tubercular spondylitis is still an infrequently fo...

متن کامل

Biomechanical evaluation of an endplate-conformed polycaprolactone-hydroxyapatite intervertebral fusion graft and its comparison with a typical nonconformed cortical graft.

In the thoracolumbar region, between 7% and 30% of spinal fusion failures are at risk for pseudarthrosis. From a biomechanical perspective, the nonconformity of the intervertebral graft to the endplate surface could contribute to pseudarthrosis, given suboptimal stress distributions. The objective of this study was to quantify the effect of endplate-graft conformation on endplate stress distrib...

متن کامل

Management of strut graft failure in anterior cervical spine surgery.

Although successfully used, long strut grafts are vulnerable to dislodgment, displacement, fracture, and nonunion, which can require revision surgery; thus, meticulous preparation of the vertebral endplate along with exact sizing and harvesting of the bone graft with plating are essential for successful outcomes. Biomechanical data and previous clinical studies support the addition of posterior...

متن کامل

بررسی ارتباط بین انحناهای ستون فقرات و درد قدام زانو

Objective: Patellofemoral pain syndrome is a common cause of anterior knee pain .This condition may arise from abnormal muscular and biomechanical factors , that alter tracking of the patella within the femoral trachlear notch , contributing to increased patellofemoral contact pressures that result in pain and dysfunction . It was suggested that there was some pathological correlation between s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013