Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT.

نویسندگان

  • E Klintström
  • O Smedby
  • B Klintström
  • T B Brismar
  • R Moreno
چکیده

OBJECTIVES The aim of this study was to evaluate how imaging parameters at clinical dental CBCT affect the accuracy in quantifying trabecular bone structures, contrast-to-noise ratio (CNR) and radiation dose. METHODS 15 radius samples were examined using CBCT (Accuitomo FPD; J. Morita Mfg., Kyoto, Japan). Nine imaging protocols were used, differing in current, voltage, rotation degree, voxel size, imaging area and rotation time. Radiation doses were measured using a kerma area product-meter. After segmentation, six bone structure parameters and CNRs were quantified. Micro-CT (μCT) images with an isotropic resolution of 20 μm were used as a gold standard. RESULTS Structure parameters obtained by CBCT were strongly correlated to those by μCT, with correlation coefficients >0.90 for all studied parameters. Bone volume and trabecular thickness were not affected by changes in imaging parameters. Increased tube current from 5 to 8 mA, decreased isotropic voxel size from 125 to 80 μm and decreased rotation angle from 360° to 180° affected correlations for trabecular termini negatively. Decreasing rotation degree also weakened correlations for trabecular separation and trabecular number at 80 μm voxel size. Changes in the rotation degree and tube current affected CNR significantly. The radiation dose varied between 269 and 1153 mGy cm(2). CONCLUSIONS Trabecular bone structure can be accurately quantified by clinical dental CBCT in vitro, and the obtained structure parameters are strongly related to those obtained by μCT. A fair CNR and strong correlations can be obtained with a low radiation dose, indicating the possibility for monitoring trabecular bone structure also in vivo.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones

OBJECTIVE This study compared the adequacy of dental cone beam computed tomography (CBCT) and micro computed tomography (micro-CT) in evaluating the structural parameters of trabecular bones. METHODS The cellular synthetic bones in 4 density groups (Groups 1-4: 0.12, 0.16, 0.20, and 0.32 g/cm3) were used in this study. Each group comprised 8 experimental specimens that were approximately 1 cm...

متن کامل

Predicting Trabecular Bone Stiffness from Clinical Cone-Beam CT and HR-pQCT Data; an In Vitro Study Using Finite Element Analysis

Stiffness and shear moduli of human trabecular bone may be analyzed in vivo by finite element (FE) analysis from image data obtained by clinical imaging equipment such as high resolution peripheral quantitative computed tomography (HR-pQCT). In clinical practice today, this is done in the peripheral skeleton like the wrist and heel. In this cadaveric bone study, fourteen bone specimens from the...

متن کامل

Correlation between lipid-lowering and bone-protective effects of eicosapentaenoic acid in rats with steroid-induced bone loss

This study was conducted to investigate the correlation between lipid-lowering and bone-protective effects of eicosapentaenoic acid on steroid-induced bonechanges in rats. Twenty-one male 10-week-old Wistar rats were divided into 3 groups (n = 7 each) and treated with 0.9% NaCl SC (group 1) or methylprednisolone 7 mg/kg SC once a week (group 2) or methylprednisolone 7 mg/kg SC once a week + eic...

متن کامل

The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: a histomorphometric analysis by micro-CT.

OBJECTIVES The aim of this study was to objectively assess the reliability of the cone-beam computed tomography (CBCT) as a tool to pre-operatively determine radiographic bone density (RBD) by the density values provided by the system, analyzing its relationship with histomorphometric bone density expressed as bone volumetric fraction (BV/TV) assessed by micro-CT of bone biopsies at the site of...

متن کامل

Histomorphometric analysis of the effects of standard heparin on trabecular bone in vivo.

Long-term heparin treatment causes osteoporosis through an as yet undefined mechanism. To investigate this phenomenon, we treated rats with once daily subcutaneous injections of heparin (in doses ranging from 0.25 to 1.0 U/g) or saline for 8 to 32 days and monitored the effects on bone both histomorphometrically and by serial measurements of urinary type 1 collagen cross linked-pyridinoline (PY...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Dento maxillo facial radiology

دوره 43 8  شماره 

صفحات  -

تاریخ انتشار 2014