Coherent Diffraction Imaging

نویسنده

  • Jianwei Miao
چکیده

For centuries, lens-based microscopy, such as light, phase-contrast, fluorescence, confocal and electron microscopy, has played an important role in the evolution of modern science and technology. In 1999, a novel form of microscopy, known as coherent diffraction imaging (CDI) or lensless imaging, was developed and transformed our traditional view of microscopy, in which the diffraction pattern of a noncrystalline object or a nanocrystal was first measured and then directly phased to obtain an image (1). The well-known phase problem is solved by combining the oversampling method with iterative algorithms. The origin of the oversampling concept can be traced back to the Shannon sampling theorem (2). When the diffraction pattern of a finite object is sampled at a frequency sufficiently finer than the Nyquist interval, the phase information is in principle encoded in the diffraction intensities (3) and can be directly retrieved by an iterative algorithm (4). Over the past decade, various CDI methods, such as plane wave CDI, Bragg CDI and ptychographic CDI, have been implemented using synchrotron radiation, X-ray free electron lasers (XFELs), high harmonic generation, optical lasers, and electrons (517).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution three-dimensional partially coherent diffraction imaging.

The wave properties of light, particularly its coherence, are responsible for interference effects, which can be exploited in powerful imaging applications. Coherent diffractive imaging relies heavily on coherence and has recently experienced rapid growth. Coherent diffractive imaging recovers an object from its diffraction pattern by computational phasing with the potential of wavelength-limit...

متن کامل

Crystal optics as guard apertures for coherent x-ray diffraction imaging.

A crucial issue in coherent x-ray diffraction imaging experiments is how to increase the signal-to-noise ratio when measuring relatively weak diffraction intensities from a nonperiodic object. A novel crystal guard aperture is described that makes use of a pair of multiple-bounce crystal optics to eliminate unwanted parasitic scattering background. This background is often produced by upstream ...

متن کامل

Phase retrieval by coherent modulation imaging

Phase retrieval is a long-standing problem in imaging when only the intensity of the wavefield can be recorded. Coherent diffraction imaging is a lensless technique that uses iterative algorithms to recover amplitude and phase contrast images from diffraction intensity data. For general samples, phase retrieval from a single-diffraction pattern has been an algorithmic and experimental challenge...

متن کامل

Resolving power of diffraction imaging with an objective: a numerical study.

Diffraction imaging in the far-field can detect 3D morphological features of an object for its coherent nature. We describe methods for accurate calculation and analysis of diffraction images of scatterers of single and double spheres by an imaging unit based on microscope objective at non-conjugate positions. A quantitative study of the calculated diffraction imaging in spectral domain has bee...

متن کامل

Coherent Bragg nanodiffraction at the hard X-ray Nanoprobe beamline.

Bragg coherent diffraction with nanofocused hard X-ray beams provides unique opportunities for quantitative in situ studies of crystalline structure in nanoscale regions of complex materials and devices by a variety of diffraction-based techniques. In the case of coherent diffraction imaging, a major experimental challenge in using nanoscale coherent beams is maintaining a constant scattering v...

متن کامل

Coherent diffractive imaging and partial coherence

We formulate coherent diffractive imaging in the framework of partially spatially coherent diffraction. We find that the reconstruction can be critically dependent on the degree of coherence in the illuminating field and that even a small departure from full coherence may invalidate the conventional assumption that a mapping exists between an exit surface wave of finite support and a far field ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014