Effect of high-frequency hearing loss on compound action potentials recorded from the intracranial portion of the human eighth nerve.
نویسندگان
چکیده
Compound action potentials (CAP) were recorded from the exposed intracranial portion of the eighth nerve to stimulation with click sounds in patients with sensorineural high-frequency hearing loss who underwent microvascular decompression (MVD) operations to treat trigeminal neuralgia (TN). In patients with normal hearing the CAP recorded in that way is characterized by a negative peak, preceded by a small positivity and followed by a positivity and sometimes a second negative peak. In patients with high-frequency hearing loss the CAP also usually had an initial sharp negative peak in response to clicks of high intensity (105 to 110 dB Pe SPL), similar to findings in patients with normal hearing, but in patients with high-frequency hearing loss the initial negative peak was often followed by a slow negative deflection. The latency of the initial negative peak in the CAP in patients with high-frequency hearing loss was longer than the latency of this peak in patients with normal hearing, but the difference in latencies of this peak to condensation and rarefaction clicks was small. When the stimulus intensity was lowered the amplitude of the initial peak decreased, and the CAP became dominated by a broad negative peak with a latency of 6 to 8 ms. In 11 of 15 patients with severe high-frequency hearing loss, a series of quasi-periodic waves was superimposed on the CAP. The frequency of these waves varied between 500 and 1200 Hz, and the waves could be detected between 6 and 16 ms after presentation of the click stimulus. These waves were usually present in the response to stimuli in the intensity range from 75 to 110 dB Pe SPL. Only 4 of 17 patients with normal hearing had similar waves.
منابع مشابه
Click-evoked responses from the exposed intracranial portion of the eighth nerve during vestibular nerve section: bipolar and monopolar recordings.
We compare the click-evoked compound action potentials from the exposed intracranial portion of the eighth nerve using bipolar and monopolar recording electrodes in patients undergoing vestibular nerve section. It is assumed that a bipolar recording electrode will only record propagated neural activity in the auditory nerve, whereas a monopolar recording electrode may in addition record electri...
متن کاملLate components in the compound action potentials (CAP) recorded from the intracranial portion of the human eighth nerve.
The compound action potential (CAP) that can be recorded from the exposed intracranial portion of the eighth nerve in man to stimulation with broadband clicks of about 100 dB Pe SPL normally has an initial (small) positivity followed by a sharp negative peak with a latency of about 3 to 3.5 ms. The negative peak is usually followed by another positive-negative deflection with a latency of about...
متن کاملResponses from the brainstem at the entrance of the eighth nerve in human to contralateral stimulation.
Recordings were made from the exposed eighth nerve (N VIII) and the lateral brainstem near the root entry zone of N VIII to contralateral click stimulation in patients undergoing microvascular decompression operations to relieve hemifacial spasm or trigeminal neuralgia. Similar recordings were made in patients undergoing operations to remove acoustic tumors using a retromastoid approach to the ...
متن کاملAcoustic Neurinomas
Acoustic neuromas (AN) are schwann cell-derived tumors that commonly arise from the vestibular portion of the eighth cranial nerve also known as vestibular schwannoma(VS) causes unilateral hearing loss, tinnitus, vertigo and unsteadiness. In many cases, the tumor size may remain unchanged for many years following diagnosis, which is typically made by MRI. In the majority of cases the tumor is s...
متن کاملVestibular Schwannomas Microsurgery Assisted by Flexible Hand-Held 2 micro-Thulium-Fiber Laser
Background: Vestibular Schwannoma (VS) is one of the skull base tumors originating from vestibular portion of eighth cranial nerve. Recently, 2 micro-Thulium laser is used in the surgery of some intracranial tumors. Objectives: Assessing the efficacy of 2 micro-Thulium flexible hand-held laser fiber (RevolixjrÒ) in microsurgical removal of VS. Materials and Methods: This retrospect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hearing research
دوره 55 1 شماره
صفحات -
تاریخ انتشار 1991