Diagnostic Accuracy of a Loop-Mediated Isothermal PCR Assay for Detection of Orientia tsutsugamushi during Acute Scrub Typhus Infection

نویسندگان

  • Daniel H. Paris
  • Stuart D. Blacksell
  • Pruksa Nawtaisong
  • Kemajittra Jenjaroen
  • Achara Teeraratkul
  • Wirongrong Chierakul
  • Vanaporn Wuthiekanun
  • Pacharee Kantipong
  • Nicholas P. J. Day
چکیده

BACKGROUND There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. METHODOLOGY/PRINCIPAL FINDINGS In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. CONCLUSIONS/SIGNIFICANCE The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly Sensitive Loop-Mediated Isothermal Amplification for the Detection of Leptospira

Leptospirosis is a worldwide zoonosis caused by an infection with the pathogenic species of Leptospira. We have developed a loop-mediated isothermal amplification (LAMP) assay to detect the DNA of Leptospira spp. Six sets of primers targeting the gene of the subsurface protein, lipL32, were evaluated for their detection sensitivity. The best primer set detected less than 25 copies of lipL32 per...

متن کامل

Accuracy of Conventional PCR Targeting the 16S rRNA Gene with the Ot-16sRF1 and Ot-16sRR1 Primers for Diagnosis of Scrub Typhus: a Case-Control Study.

We retrospectively evaluated the accuracy of conventional PCR targeting the 16S rRNA gene (16S C-PCR) using the Ot-16sRF1/Ot-16sRR1 primers for diagnosing scrub typhus. The diagnosis of Orientia tsutsugamushi infection by 16S C-PCR presented an increased sensitivity of 87.0% and specificity of 100% compared with those obtained with other targets and is thus a simple and clinically useful method...

متن کامل

A highly sensitive quantitative real-time PCR assay based on the groEL gene of contemporary Thai strains of Orientia tsutsugamushi

Partial nucleotide sequences (459 bp) of the groEL gene (encoding the 60-kDa heat shock protein, HSP60) from 23 contemporary isolates of Orientia tsutsugamushi isolated from patients with acute scrub typhus in Thailand were compared with 16 reference strain sequences to evaluate the potential of groEL as a conserved and representative target for molecular diagnostics.. Overall nucleotide identi...

متن کامل

Improvement of the Diagnostic Sensitivity of Scrub Typhus Using a Mixture of Recombinant Antigens Derived from Orientia tsutsugamushi Serotypes

Diagnosis of scrub typhus is difficult because its symptoms are very similar to other acute febrile illnesses, such as leptospirosis, murine typhus, and other viral hemorrhagic fevers. To differentiate scrub typhus from other acute febrile diseases, a rapid and reliable serological diagnosis is important. We have developed a chimeric recombinant antigen cr56 and two other recombinant antigens, ...

متن کامل

Diagnostic Accuracy Assessment of Immunochromatographic Tests for the Rapid Detection of Antibodies against Orientia tsutsugamushi Using Paired Acute and Convalescent Specimens

We assessed the diagnostic accuracy of two immunochromatographic tests (ICTs), the Access Bio CareStart Scrub Typhus test (Somerset, NJ) (IgM), and the SD BIOLINE Tsutsugamushi test (Kyonggi-do, Republic of Korea) (IgG, IgM, or IgA) compared with indirect immunofluorescence assay (IFA) and real-time PCR results as reference tests using 86 paired acute and convalescent specimens from febrile pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011