Three Dimensional Digital Polyhedral Phantom Framework with Analytical Fourier Transform and Application in Cardiac Imaging

نویسندگان

  • T. M. Ngo
  • G. S. Fung
  • B. M. Tsui
  • E. McVeigh
  • D. A. Herzka
چکیده

Introduction: Physiologically relevant computer simulations involving digital phantoms are commonly used to test new MR acquisition and reconstruction strategies in cases where real experiments are unfeasible or impractical. Although these phantoms are constructed in the image domain, since MR samples Fourier space, these phantoms must also provide an accurate Continuous Fourier Transform (CFT) representation. However, computing the CFT at any arbitrary point in k-space from an image domain description of a phantom can be difficult. Voxel-based phantoms approximate the CFT by computing the Discrete Fourier Transform (DFT) of a super-sampled image of the phantom. This approach is both computationally inefficient and not directly applicable when non-Cartesian k-space sampling patterns are desired. Alternatively, analytical phantoms are constructed using geometric primitives such as ellipsoids, whose CFT are known analytically [1]. To date, this approach has been limited because these primitives are unable to model complicated anatomical shapes. Here, we extend this approach and present a framework that allows realistic 3-D digital phantoms to be created from general polyhedra which also have an analytical CFT solution. Polyhedra are closed surfaces comprised of polygonal faces and include standard triangular meshes widely used in 3-D computer modeling. We demonstrate the value of the framework with a simple experiment in which we created a realistic MR heart phantom derived from the 4-D eXtended CArdiac Torso (XCAT) phantom and simulated motion artifacts which arise during segmented, cardiac gated cine acquisitions. Methods: Komrska [2] derives the analytical solution for the Fourier transform of a constant unitary valued polyhedral solid at position as: ∑ , , ∑ exp 2 , 2 exp 2 , Where V is the volume of the polyhedron and is the area of the f face given respectively as [3]: 16 12 Let : total faces, : unit normal of f face, : length of e edge of f face, : total edges in f face, : position vector of the midpoint of e edge on f face, : Unit vector in the direction of e edge of f face, : Length of e edge of f face, : outward normal to e edge of f face in the plane of face , : position vector of e vertex of f face ordered counterclockwise when viewed against , : magnitude of . Edge e on face f points from vertex to . Additionally, the first and last vertices are connected, thus and likewise . Fig. 1 illustrates these vectors. Implementation: The framework is implemented as a Matlab C++ plug-in, parallelized using the cross platform ITK library. The cost of computing the CFT of the phantom is linear with the number of polygonal faces and k-space samples. The face contributions can be computed in parallel. A quad core Intel Xeon 2.13Ghz system computes a 51x51x51 matrix, or 132,651 k-space samples for a polyhedron with 1,612 triangular faces in ~110 seconds (3 run average), 0.5136 μseconds/sample/face. Experiment: Using our framework, we created a realistic phantom of the beating left and right ventricles which were then used to simulate a standard Cartesian segmented, cardiac gated cine acquisition. The XCAT phantom, which derives both geometry and motion from human physiological measurements [4], provided triangular meshes for the polyhedral phantom. 100 evenly spaced snapshots of the left and right ventricle throughout a cardiac cycle were generated from the non-uniform rational B-spline (NURBS) surfaces of the XCAT heart model. Each snapshot provided separate triangular meshes for the endocardial and epicardial surfaces of the left and right ventricles for a total of 13,000 faces per time sample. Fig. 2 illustrates these meshes at systole. We then simulated a 3-D cine segmented Cartesian acquisition with the following parameters: Heart rate: 60 BPM, TR: 3.5 ms, 15/9/5 phase encodes per segment (18/30/48 cardiac phases, 52.5/27/17.5 ms, ~19/37/57 Hz temporal resolution), matrix size 128, FOV 100x112x80 mm yielding a physically unachievable resolution of 0.77x0.87x0.625 mm. Results: Fig. 3 shows long and short axis slices of the inverse DFT reconstructed volume at cardiac phases corresponding to end systole, shortly after systole, and mid-diastole. As expected, images of the semi-quiescent periods at end-systole and mid-diastole are relatively artifact free, regardless of sampling rate, while those during iso-volumic relaxation exhibit motion artifacts. These artifacts are edge enhanced ghosts similar to those observed during real acquisitions [5]. The white boundary in the septum is caused by correctible overlap between the meshes. Conclusion: Previously presented analytical phantoms could not represent complex anatomical shapes. Using polyhedra, our framework allows construction of realistic digital phantoms that still have an analytical CFT. This is particularly useful for non-Cartesian acquisition techniques. Though not shown here, the 4D XCAT includes thousands of anatomically correct structures, including the chest wall, larger vasculature, and coronary arteries, and models both cardiac and respiratory motion. Using our framework in conjunction with meshes derived from the XCAT phantom will provide physiologically realistic image and k-space gold standards, thus facilitating the development of acquisition, motion compensation, and reconstruction techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Realistic analytical polyhedral MRI phantoms.

PURPOSE Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing three-dimensional (3D) analytical phantoms are unable to accurately model shapes of biomedical interest. The goal of this study was to demonstrate that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedic...

متن کامل

Four-Dimensional Analytical Cardiac Magnetic Resonance Imaging Phantom in the Fourier Domain

Introduction A 2D analytical cardiac magnetic resonance imaging (MRI) phantom in the Fourier domain was introduced by Brummer et al. [1] to compare acceleration strategies based on a reduction of the field of view. In related work by our group and others the value of a standardized simulation phantom to test and compare reconstruction methods for cardiac imaging has become evident. In this work...

متن کامل

Energy window setting for optimum Tl-201 cardiac imaging [Persian]

  Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...

متن کامل

Three-dimensional analytical magnetic resonance imaging phantom in the Fourier domain.

This work presents a basic framework for constructing a 3D analytical MRI phantom in the Fourier domain. In the image domain the phantom is modeled after the work of Kak and Roberts on a 3D version of the famous Shepp-Logan head phantom. This phantom consists of several ellipsoids of different sizes, orientations, locations, and signal intensities (or gray levels). It will be shown that the k-s...

متن کامل

Model-Free and Analytical EAP Reconstruction via Spherical Polar Fourier Diffusion MRI

How to estimate the diffusion Ensemble Average Propagator (EAP) from the DWI signals in q-space is an open problem in diffusion MRI field. Many methods were proposed to estimate the Orientation Distribution Function (ODF) that is used to describe the fiber direction. However, ODF is just one of the features of the EAP. Compared with ODF, EAP has the full information about the diffusion process ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010