Repetitive monomorphic ventricular tachycardia originating from the aortic sinus cusp: electrocardiographic characterization for guiding catheter ablation.
نویسندگان
چکیده
OBJECTIVES We sought to investigate the electrocardiographic (ECG) characteristics for guiding catheter ablation in patients with repetitive monomorphic ventricular tachycardia (RMVT) originating from the aortic sinus cusp (ASC). BACKGROUND Repetitive monomorphic ventricular tachycardia can originate from the right ventricular outflow tract (RVOT) and ASC in patients with a left bundle branch block (LBBB) morphology and an inferior axis. METHODS Activation mapping and ECG analysis was performed in 15 patients with RMVT or ventricular premature contractions. The left main coronary artery (LMCA) was cannulated as a marker and for protection during radiofrequency delivery if RMVT originated from the left coronary ASC. RESULTS During arrhythmia, the earliest ventricular activation was recorded from the superior septal RVOT in eight patients (group 1) and from the ASC in the remaining seven patients (group 2). The indexes of R-wave duration and R/S-wave amplitude were significantly lower in group 1 than in group 2 (31.8+/-13.5% vs. 58.3+/-12.1% and 14.9+/-9.9% vs. 56.7+/-29.5%, respectively; p < 0.01), despite similar QRS morphology. In five patients from group 2, RMVT originated from the left ASC, with a mean distance of 12.2+/-3.2 mm (range 7.3 to 16.1) below the ostium of the LMCA. In the remaining two patients, the RMVT origin was in the right ASC. All arrhythmias were successfully abolished. None of the patients had recurrence or complications during 9+/-3 months of follow-up. CONCLUSIONS On the surface ECG, RMVT from the ASC has a QRS morphology similar to that of RVOT arrhythmias. The indexes of R-wave duration and R/S-wave amplitude can be used to differentiate between the two origins. Radiofrequency ablation can be safely performed within the left ASC with a catheter cannulating the LMCA.
منابع مشابه
Radiofrequency Catheter Ablation with the Use of a Noncontact Mapping System for Ventricular Tachycardia Originating from the Aortic Sinus Cusp —A Case Report—
Here we present a 15-year old female in whom an idiopathic ventricular tachycardia (VT) originating from the left aortic sinus cusp was eliminated by radiofrequency catheter ablation (RFCA) under navigation using a noncontact mapping system (NCM). The dynamic activation map constructed with the NCM clearly identified a VT focus in the left aortic sinus cusp, from which the activation spread out...
متن کاملDynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract
Electrocardiographic characteristics can be useful in differentiating between right ventricular outflow tract (RVOT) and aortic sinus cusp (ASC) ventricular arrhythmias. Ventricular arrhythmias originating from ASC, however, show preferential conduction to RVOT that may render the algorithms of electrocardiographic characteristics less reliable. Even though there are few reports describing vent...
متن کاملShort-term results of substrate mapping and radiofrequency ablation of ischemic ventricular tachycardia using a saline-irrigated catheter.
OBJECTIVES We evaluated the safety and acute procedural efficacy of a combined electrophysiologic and anatomic approach to ablation of all inducible ventricular tachycardias (VT) during sinus rhythm using an irrigated radiofrequency (RF) ablation catheter. BACKGROUND Ventricular tachycardia associated with chronic myocardial infarction (MI) is frequently hemodynamically intolerable and associ...
متن کاملPrevalence and clinical, electrocardiographic, and electrophysiologic characteristics of ventricular arrhythmias originating from the noncoronary sinus of Valsalva.
BACKGROUND Idiopathic ventricular arrhythmias (VAs) can be rarely ablated from the noncoronary cusp (NCC) of the aorta. OBJECTIVE The purpose of this study was to investigate the prevalence and the clinical, electrocardiographic, and electrophysiologic characteristics of idiopathic NCC VAs. METHODS We studied 90 consecutive patients who underwent successful catheter ablation of idiopathic a...
متن کاملDevelopment of a magnetocardiography-based algorithm for discrimination between ventricular arrhythmias originating from the right ventricular outflow tract and those originating from the aortic sinus cusp: a pilot study.
BACKGROUND Although several reports address characteristic 12-lead electrocardiographic findings of outflow tract ventricular arrhythmias (OT-VAs), the accuracy of electrocardiogram-based algorithms to predict the OT-VA origin is sometimes limited. OBJECTIVE This study aimed to develop a magnetocardiography (MCG)-based algorithm using a novel adaptive spatial filter to differentiate between V...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2002