Effects of brain membranes on 1H nuclear magnetic resonance signal intensity of ethanol in vitro.

نویسندگان

  • V Govindaraju
  • D J Meyerhoff
  • A A Maudsley
  • M Vermathen
  • M W Weiner
چکیده

In vivo proton nuclear magnetic resonance (1H NMR) studies of ethanol in animal and human brains have shown that only a fraction of ethanol in brain is visible by NMR. The goals of these in vitro 1H NMR experiments were to determine: (1) whether the interaction of ethanol with brain membranes in vitro diminishes ethanol visibility; and (2) if a magnetization transfer (MT) effect can be observed for the interaction of ethanol with brain membranes in vitro. Furthermore, pilot studies were performed to determine if the brain membranes from rats chronically exposed to ethanol had a different effect on ethanol NMR visibility and spin-spin relaxation time (T2) than brain membranes obtained from control rats. Results show that the NMR visibility of ethanol is lower in rat brain membrane suspensions in vitro as compared to ethanol in saline solutions. The factors decreasing ethanol NMR visibility are T2 relaxation, water presaturation time, and off-resonance saturation by a frequency-dependent MT pulse. One-pulse NMR measurements without water presaturation showed that ethanol visibility was significantly increased by 15% in brain membrane suspensions of ethanol-fed rats, suggestive of decreased ethanol partitioning compared to controls. Furthermore ethanol in brain membrane suspensions from ethanol-fed rats showed smaller MT effects than from control rats. These results provide a mechanism for decreased NMR visibility of ethanol in brain, and suggest that chronic exposure to ethanol produces membrane changes which result in increased NMR visibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافته‌های Magnetic Resonance Imaging

Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Quantitative analysis of apoptotic cell death using proton nuclear magnetic resonance spectroscopy.

Quantification of apoptotic cell death in vivo has become an important area of investigation in patients with acute lymphoblastic leukemia (ALL). We have devised a noninvasive analytical method to estimate the percentage of apoptotic lymphoblasts in doxorubicin-treated Jurkat T-cell ALL cultures, using proton nuclear magnetic resonance spectroscopy (1H NMR). We have found that the ratio of the ...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Alcohol and alcoholism

دوره 32 6  شماره 

صفحات  -

تاریخ انتشار 1997