Hemodynamic changes associated with spinal anesthesia for cesarean delivery in severe preeclampsia.

نویسندگان

  • Robert A Dyer
  • Jenna L Piercy
  • Anthony R Reed
  • Carl J Lombard
  • Leann K Schoeman
  • Michael F James
چکیده

BACKGROUND Hemodynamic responses to spinal anesthesia (SA) for cesarean delivery in patients with severe preeclampsia are poorly understood. This study used a beat-by-beat monitor of cardiac output (CO) to characterize the response to SA. The hypothesis was that CO would decrease from baseline values by less than 20%. METHODS Fifteen patients with severe preeclampsia consented to an observational study. The monitor employed used pulse wave form analysis to estimate nominal stroke volume. Calibration was by lithium dilution. CO and systemic vascular resistance were derived from the measured stroke volume, heart rate, and mean arterial pressure. In addition, the hemodynamic effects of phenylephrine, the response to delivery and oxytocin, and hemodynamics during recovery from SA were recorded. Hemodynamic values were averaged for defined time intervals before, during, and after SA. RESULTS Cardiac output remained stable from induction of SA until the time of request for analgesia. Mean arterial pressure and systemic vascular resistance decreased significantly from the time of adoption of the supine position until the end of surgery. After oxytocin administration, systemic vascular resistance decreased and heart rate and CO increased. Phenylephrine, 50 mug, increased mean arterial pressure to above target values and did not significantly change CO. At the time of recovery from SA, there were no clinically relevant changes from baseline hemodynamic values. CONCLUSIONS Spinal anesthesia in severe preeclampsia was associated with clinically insignificant changes in CO. Phenylephrine restored mean arterial pressure but did not increase maternal CO. Oxytocin caused transient marked hypotension, tachycardia, and increases in CO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COMPARISON OF HEMODYNAMIC CHANGES DUE TO INTRAVENOUS OXYTOCIN INFUSION DURING GENERAL AND SPINAL ANESTHESIA IN ELECTIVE CESAREAN SECTION

Background & Aims: Postpartum hemorrhage is one of the life-threatening complications after labor and cesarean section. Its prevalence is 6 percent. Metratonia is the most common cause of this complication. Some medications can prevent it. Oxytocin is the most common uterine vasoconstrictor and is used routinely after delivery for decreasing hemorrhage. The aim of this study is to compare hemod...

متن کامل

The Effect of Prophylactic Infusion of Combined Ephedrin and Phenylephrine on Maternal Hemodynamic after Spinal Anesthesia for Cesarean Section: A Randomized Clinical Trial

Several techniques have been proposed to prevent hypotension in obstetric patients. Ephedrine and phenylephrine are individually used to prevent maternal hypotension; however, each has its own drawbacks. Some researchers have reported that the infusion of combined ephedrine and phenylephrine immediately after spinal anesthesia for cesarean delivery reduces the incidence of maternal hypotension....

متن کامل

Efficacy of epidural and spinal anesthesia techniques in preeclampsia parturients

Background: Preeclampsia is a hypertensive related complication of pregnancy; Parturients with pregnancy induced hypertension may present to the labor and delivery unit with or without a prior diagnosis of preeclampsia and may pose a significant anesthetic challenge. Administration of anesthesia in such cases leads to worse cardiovascular response. Objectives: To determine the efficacy of epidu...

متن کامل

Comparison of Apgar score in new born by vaginal delivery and spinal anesthesia and its relationship with contributing factors

Introduction: Apgar score evaluation is a common method to evaluate physiological changes of newborns and can help to predict the neonatal life chance. This study was conducted to determine the Apgar score of newborns with two methods of vaginal delivery and spinal anesthesia and its relationship with the associated factors in Gorgan health care facility. Materials and methods: A cross-sec...

متن کامل

Comparison of Spinal Anesthesia in L3-L4 and L4-L5 on Sensory-Motor Block Level and Hemodynamic Status in Cesarean Section

Background and Objective: The injection site in spinal anesthesia is one of the factors that can affect the height of the sensory block. This clinical trial study aimed to compare the effect of spinal anesthesia at L3-L4 and L4-L5 on the level of sensory-motor block and hemodynamic status in cesarean section. Materials and Methods: Seventy patients undergoing elective cesarean section and rece...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 108 5  شماره 

صفحات  -

تاریخ انتشار 2008