Second and Third Harmonic Measurements at the Linac Coherent Light Source

نویسندگان

  • D. Ratner
  • A. Brachmann
  • F. J. Decker
  • Y. Ding
  • D. Dowell
  • P. Emma
  • J. Frisch
  • Z. Huang
  • R. Iverson
  • J. Krzywinski
  • H. Loos
  • M. Messerschmidt
  • H. D. Nuhn
  • T. Smith
  • J. Turner
  • J. Welch
  • W. White
  • J. Wu
  • R. Bionta
چکیده

The Linac Coherent Light Source (LCLS) started user commissioning in October of 2009, producing Free Electron Laser (FEL) radiation between 800 eV and 8 keV [1]. The fundamental wavelength of the FEL dominates radiation in the beamlines, but the beam also produces nonnegligible levels of radiation at higher harmonics. The harmonics may be desirable as a source of harder X-rays, but may also contribute backgrounds to user experiments. In this paper we present preliminary measurements of the second and third harmonic content in the FEL. We also measure the photon energy cutoff of the soft X-ray mirrors to determine the extent to which higher harmonics reach the experimental stations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generation of GW - level , sub - Angstrom Radiation in the LCLS using a Second - Harmonic Radiator ∗

Electron beams are strongly microbunched near the high-gain free-electron laser (FEL) saturation with a rich harmonic content in the beam current. While the coherent harmonic emission is possible in a planar undulator, the thirdharmonic radiation typically dominates with about 1% of the fundamental power at saturation. In this paper, we discuss the second-harmonic radiation in the Linac Coheren...

متن کامل

Optical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring

The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...

متن کامل

Commissioning of the Lcls Linac and Bunch Compressors*

The Linac Coherent Light Source (LCLS) is a SASE xray Free-Electron Laser (FEL) project under construction at SLAC [1]. The injector section, from drive-laser and RF photocathode gun through the first bunch compressor, was commissioned in the spring and summer of 2007. The second phase of commissioning, including the second bunch compressor and various main linac modifications, was completed in...

متن کامل

Linac Design for Dalian Coherent Light Source*

Dalian Coherent Light Source (DCLS) will use a 300MeV LINAC to produce fully coherent photon pulses in the wavelength range between 150-50nm by high gain harmonic generation free electron laser (FEL) scheme [1]. Beam quality requirements for the linear accelerator (linac) are critical, including not only the beam brightness, but also the stability and the reliability. In this paper, optimizatio...

متن کامل

Design Considerations for a 60 Meter Pure Permanent Magnet Undulator for the SLAC Linac Coherent Light Source (LCLS)

In this paper we describe design, fabrication , and measurement aspects of a pure permanent magnet (PM) insertion device designed to operate as an FEL at a 1st harmonic energy of 300 eV and an electron energy of 7 GeV in the Self-Amplified Spontaneous Emission (SASE) regime.