Optimal acetabular orientation for hip resurfacing.

نویسندگان

  • G Grammatopoulos
  • H Pandit
  • S Glyn-Jones
  • P McLardy-Smith
  • R Gundle
  • D Whitwell
  • H S Gill
  • D W Murray
چکیده

Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation. We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47 degrees, 10 degrees to 81 degrees) and anteversion angle (14 degrees, 4 degrees to 34 degrees) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46 degrees (29 degrees to 60 degrees) and 16 degrees (4 degrees to 30 degrees) respectively, but the variation was greater. Assuming an accuracy of implantation of +/- 10 degrees about a target position, the optimal radiographic position was found to be approximately 45 degrees of inclination and 20 degrees of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone. In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45 degrees (+/- 10) and anteversion of 20 degrees (+/- 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40 degrees and an anteversion of 25 degrees.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal acetabular component orientation estimated using edge-loading and impingement risk in patients with metal-on-metal hip resurfacing arthroplasty.

Edge-loading in patients with metal-on-metal resurfaced hips can cause high serum metal ion levels, the development of soft-tissue reactions local to the joint called pseudotumours and ultimately, failure of the implant. Primary edge-loading is where contact between the femoral and acetabular components occurs at the edge/rim of the acetabular component whereas impingement of the femoral neck o...

متن کامل

Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography

PURPOSE The orientation of the acetabular component in metal-on-metal hip resurfacing arthroplasty affects wear rate and hence failure. This study aimed to establish if interpretation of pelvic radiographs with TraumaCad software can provide a reliable alternative to CT in measuring the acetabular inclination and version. METHODS TraumaCad was used to measure the acetabular orientation on AP ...

متن کامل

Birmingham hip resurfacing: is acetabular bone conserved?

Hip resurfacing is a bone-conserving procedure with respect to proximal femoral resection, but there is debate in the literature as to whether the same holds true for the acetabulum. We have investigated whether the Birmingham hip resurfacing conserves acetabular bone. Between 1998 and 2005, 500 Birmingham hip resurfacings were performed by two surgeons. Between 1996 and 2005 they undertook 700...

متن کامل

A comparison of explanted Articular Surface Replacement and Birmingham Hip Resurfacing components.

The Articular Surface Replacement (ASR) hip resurfacing arthroplasty has a failure rate of 12.0% at five years, compared with 4.3% for the Birmingham Hip Resurfacing (BHR). We analysed 66 ASR and 64 BHR explanted metal-on-metal hip replacements with the aim of understanding their mechanisms of failure. We measured the linear wear rates of the acetabular and femoral components and analysed the c...

متن کامل

Individual motion patterns during gait and sit-to-stand contribute to edge-loading risk in metal-on-metal hip resurfacing.

The occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty has been associated with higher than normal bearing wear and high serum metal ion levels although both these findings do not necessarily coexist. The purpose of this study was to examine patient activity patterns and their influence on acetabular component edge lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 8  شماره 

صفحات  -

تاریخ انتشار 2010