Inter-study reproducibility of interleaved spiral phase velocity mapping of renal artery haemodynamics
نویسندگان
چکیده
BACKGROUND Qualitative and quantitative assessment of renal blood flow is valuable in the evaluation of patients with renal and renovascular diseases as well as in patients with heart failure. The temporal pattern of renal flow velocity through the cardiac cycle provides important information about renal haemodynamics. High temporal resolution interleaved spiral phase velocity mapping could potentially be used to study temporal patterns of flow and measure resistive and pulsatility indices which are measures of downstream resistance. METHODS A retrospectively gated breath-hold spiral phase velocity mapping sequence (TR 19 ms) was developed at 3 Tesla. Phase velocity maps were acquired in the proximal right and left arteries of 10 healthy subjects in each of two separate scanning sessions. Each acquisition was analysed by two independent observers who calculated the resistive index (RI), the pulsatility index (PI), the mean flow velocity and the renal artery blood flow (RABF). Inter-study and inter-observer reproducibility of each variable was determined as the mean +/- standard deviation of the differences between paired values. The effect of background phase errors on each parameter was investigated. RESULTS RI, PI, mean velocity and RABF per kidney were 0.71+/- 0.06, 1.47 +/- 0.29, 253.5 +/- 65.2 mm/s and 413 +/- 122 ml/min respectively. The inter-study reproducibilities were: RI -0.00 +/- 0.04 , PI -0.03 +/- 0.17, mean velocity -6.7 +/- 31.1 mm/s and RABF per kidney 17.9 +/- 44.8 ml/min. The effect of background phase errors was negligible (<2% for each parameter). CONCLUSIONS High temporal resolution breath-hold spiral phase velocity mapping allows reproducible assessment of renal pulsatility indices and RABF.
منابع مشابه
Inter breath-hold reproducibility of temporal patterns of coronary artery blood flow
Background While blood flow in the majority of arteries peaks in systole, the rhythmic squeezing of the coronary arteries and microcirculation as the heart beats results in left anterior descending artery (LAD) flow being diastolicpredominant while for the right coronary artery (RCA), there is approximately equal flow in systole and diastole. These temporal flow patterns can provide important i...
متن کاملValidation of high temporal resolution spiral phase velocity mapping of coronary artery blood flow against Doppler flow wire
Background The temporal pattern of coronary artery flow velocity through the cardiac cycle provides important information about coronary haemodynamics. The ‘gold standard’ for coronary artery velocity assessment is the Doppler flow wire which is inserted directly into the coronary artery under X-ray fluoroscopic guidance, which is invasive, uses ionising radiation and has a small but significan...
متن کاملInterleaved spiral cine coronary artery velocity mapping.
Navigator-echo controlled interleaved spiral cine coronary-artery velocity maps were acquired in eight free-breathing volunteers. Good quality data were achieved in all subjects with phasic flow being clearly demonstrated. The improved efficiency of spiral k-space coverage compared to that of more conventional spin-warp techniques resulted in a mean scan time for 256 x 256 pixel-matrix studies ...
متن کاملComparison of spiral and FLASH phase velocity mapping, with and without breath-holding, for the assessment of left and right coronary artery blood flow velocity.
PURPOSE To develop high temporal resolution coronary artery spiral phase velocity mapping sequences and to compare the results obtained with those from FLASH sequences. MATERIALS AND METHODS Velocity curves were obtained in eight left and eight right coronary arteries using breath-hold interleaved spiral (BH_SP), free-breathing interleaved spiral (FB_SP), breath-hold segmented FLASH (BH_FL), ...
متن کاملReproducibility of functional aortic analysis using MRI: the multi-ethnic study of atherosclerosis
Methods Twenty-five participants underwent aortic MRI twice over 13 ± 7 days. All aortic variables (ascending aortic area, descending aortic area, ascending and descending aortic strain [maximum area minus minimum area divided by minimum area], aortic arch transit time and pulse wave velocity [PWV]) from baseline and repeat MR were analyzed using a semi-automated method by the ARTFUN software. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2015